Complete Automatic Pacing Threshold Utilization Recorded by EnPulse

Medtronic Cardiac Rhythm and Heart Failure56 个研究点 分布在 1 个国家目标入组 860 人开始时间: 2004年3月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
860
试验地点
56
主要终点
The automatic device features Atrial Capture Management and Ventricular Capture Management measure pacing thresholds and is compared to manual pacing thresholds observed at the 6 month follow-up visit

研究概览

简要总结

This study compares the pacemaker's automatic pacing threshold measurements to the manual measurements conducted by a health care provider.

详细描述

The purpose(s) of the study is (are) to evaluate several features available in EnPulse Series pacemaker and report the long term benefit of Atrial Capture Management (ACM) and Ventricular Capture Management (VCM) as demonstrated by accuracy in comparison with manual measurements and variability of ACM and VCM thresholds.

In addition, an evaluation of the timesaving and qualitative benefits of the device feature known as Quick Look II (the computer interface screen of the device programmer) will be measured through the use of a questionnaire completed by the health care professionals involved in patient follow-up care.

This is a one-to-one randomized, multicenter, prospective study in which patients receiving new EnPulse pacemaker implants will be randomized to each of three study arms, 1) routine manual follow-up and follow-up using the automatic features; 2) ACM diagnostics detail on or VCM diagnostics detail on; 3) PMOP on / off or PMOP off / on (6 month cycle).

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Factorial
盲法
None

入排标准

性别
All
接受健康志愿者
否

入选标准

  • •Patients that meet ACC/AHA/NASPE 2002 class I or II dual chamber pacing indications (intended for a Pacing Mode programmed to DDD or DDDR)

排除标准

  • •Patient with mechanical tricuspid heart valves
  • •Patients with medical conditions that preclude the testing required by the protocol or limit study participation

结局指标

主要结局

The automatic device features Atrial Capture Management and Ventricular Capture Management measure pacing thresholds and is compared to manual pacing thresholds observed at the 6 month follow-up visit

次要结局

  • Observe the variability of multiple pacing thresholds measured with ACM and VCM
  • Observe visit time differences using automatic measurements versus traditional follow-up
  • Observe the effects of Post Mode Switch Overdrive Pacing (PMOP) on AT/AF burden.