跳至主要内容
临床试验/NCT06299449
NCT06299449已完成不适用

Clinical and Radiographic Outcomes of Computer Guided Immediate Implant Placement Utilizing Artificial Intelligence Assisted Socket Shield Approach: Randomized Clinical Trial

Kafrelsheikh University2 个研究点 分布在 1 个国家目标入组 22 人开始时间: 2024年3月5日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
22
试验地点
2
主要终点
Stability Quotient of dental implant

研究概览

简要总结

Aim of the current randomized clinical trial is to evaluate and compare the effectiveness of computer-guided immediate implant placement performed simultaneously with artificial intelligence assisted socket shield technique versus conventional approach.

详细描述

Guided implant surgery was used in dental implant surgery to achieve accuracy and an overall predictability. Successful guided implant workflow depends on 3-dimensional image acquisition and precise model fabrication.

Artificial intelligence application in implant dentistry has ushered in a new era of precision and efficiency demonstrating improved implant survival rates and patient satisfaction and enhance the integration of technologies with digital workflows.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Double (Investigator, Outcomes Assessor)

入排标准

年龄范围
19 Years 至 40 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • above the age of 18years
  • presence of non-restorable maxillary anterior tooth
  • had intact socket walls following tooth extraction
  • the gingival biotype was thick.

排除标准

  • history of systemic condition
  • history of using bisphosphonates or other drugs that might impact bone turnover
  • a history of smoking during the previous five years,
  • a history of any acute infections at the surgical site,
  • teeth having root resorptions

研究组 & 干预措施

control group

Experimental

conventional socket shield with conventional simultaneous implant placement

干预措施: free-hand socket shield (Procedure)

study group

Experimental

computer guided implant placement combined with artificial intelligence-assisted socket shield.

干预措施: AI/guided socket shield (Procedure)

结局指标

主要结局

Stability Quotient of dental implant

时间窗: 9-month.

Osstell TM was used to record the primary stability.ISQ, or Implant Stability Quotient, is a scale from 1 to 100 and is a measure of the stability of an implant. The ISQ scale has a non-linear correlation to micro mobility. With more than 1400 scientific references, investigators now know that high stability means \>70 ISQ, between 60-69 is medium stability and \< 60 ISQ is considered as low stability

facial marginal bone level

时间窗: 9-month

Utilizing CBCT sagittal sections, the BMBL was evaluated by computerized analysis. Navigation was done on the multiplanar display until the implant's precise same-view location was established on the reformatted cross-sectional section and panoramic view.

pink esthetic score

时间窗: 9-month.

The pink esthetic score (PES) evaluates the esthetic outcome of soft tissue around implant-supported single crowns in the anterior zone by awarding seven points for the mesial and distal papilla, soft-tissue level, soft-tissue contour, soft-tissue color, soft-tissue texture, and alveolar process deficiency.Using a 0-1-2 scoring system, 0 being the lowest, 2 being the highest value, the maximum achievable PES was 14

Midfacial Mucosal Alterations

时间窗: 9-month.

digital intraoral scans were recorded. To quantify the vertical changes in the soft tissues around implants buccally, the collected scans were digitally superimposed via matching Gom inspect software

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Walid Elamrousy

Assistant Professor of periodontology

Kafrelsheikh University

研究点 (2)

Loading locations...

相似试验