Evaluation of the Reliability of a Non-invasive Tool for Measuring Hemoglobin in Severe Trauma Patients in the Emergency Room
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 100
- 试验地点
- 3
- 主要终点
- the impact Hb Oxymeter
研究概览
简要总结
The development of miniaturized analytical technologies has facilitated the gradual decentralization of part of the laboratory examinations to the patient.
In addition, investigators are currently seeing the development of tools for non-invasive measurement of certain biological parameters. Thanks to their ease of use, results are obtained almost immediately and with good performance. These "rapid" tests or techniques should, in theory, reduce the time taken to take charge of patients, particularly in emergencies or in critical situations where the therapeutic decision should be as rapid and efficient as possible. These means, by their ease and speed of results, could be associated with the clinical examination of the practitioner to increase his diagnostic performance.
详细描述
It should be remembered that the journey of samples from the emergency room to the central laboratory, then the return of results is broken down into three phases: 1) the pre-analytical phase which includes medical prescription, sampling, request for analysis and delivery to 'at the central laboratory; 2) the analytical phase, specific to the laboratory, and which includes handling the sample and the analysis itself. This stage ends with the provision of the results (computer notification) and 3) the third stage (post analytical) represents the time between the provision of the results, their reading and their interpretation. All of these three phases constitute the recognized prescription-results-treatment time: Therapeutic Turn-around Time (TTAT). The main objective of these revolutionary techniques is to reduce this time or the duration of these three stages.
Several techniques, in particular delocalized biology, have been evaluated and validated in emergencies or even at home. In addition, non-invasive means remain underestimated in terms of relevance and reliability, mainly by lack of evaluation.
These measurement techniques relocated to the patient's bed allow rapid, non-invasive measurement without the need for intravenous access or the need to draw venous, arterial or capillary blood. These non-invasive devices can be portable, inexpensive, easy to use, and offer great benefits especially in emergency departments and pre-hospital settings. The accuracy of these methods is acceptable in the stable ICU patient. But that remains unassessed in an emergency.
Pulse co-oximetry or low perfusion oximetry is one of these technological advances being designed to allow the measurement of hemoglobin in a non-invasive manner. In addition, the automated spectrophotometric detection technique from a blood sample represents the Gold standard for the measurement of hemoglobin and has been recommended for several decades by the International Committee for Standardization in Hematology. This technique, performed in a hematology laboratory, allows precise, reliable and reproducible measurement. However, it requires a blood sample and above all imposes an incompressible delay. This dosage is one of the most prescribed samples in current practice in the emergency room. The possibility of determining the hemoglobin concentration in the patient's bed and non-invasively is a very attractive solution for the emergency physician.
The value of such a technique in trauma pathology seems indisputable. In fact, injuries represent a major problem for public health, representing more than 9% of deaths in the world each year. In particular, post-traumatic hemorrhage is the most common cause of preventable deaths, accounting for 50% of preventable deaths in the first 24 hours after major trauma. Early detection of hypovolaemia due to hemorrhage can be difficult, but essential for the patient's prognosis through an appropriate and adapted transfusion strategy. The hemoglobin dosage is essential for the emergency physician. Therefore, in the hospital setting, there is growing interest in rapid techniques for measuring hemoglobin.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 4 Years 至 —(Child, Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Severe trauma patients
- •Patients having benefited from a blood sample to measure hemoglobin.
排除标准
- •Patients less than 3 years old.
结局指标
主要结局
the impact Hb Oxymeter
时间窗: during the intervention
the impact Hb Oxymeter
Accuracy
时间窗: during the intervention
The accuracy of Hb Oxymeter
次要结局
未报告次要终点
研究者
Riadh Boukef
PROFESSOR
Hôpital Universitaire Sahloul