简要总结

The objective of this study is to assess the safety and effectiveness of the Endologix Nellix® System for the endovascular repair of infrarenal abdominal aortic aneurysms (AAA).

详细描述

This study will evaluate the safety and effectiveness of the Nellix System among a wide range of physicians and in consecutively enrolled subjects to assess outcomes generalizability. Following appropriate government and ethics committee/IRB approval the Nellix® EndoVascular Sealing System will be implanted into eligible patients who are adequately informed and have consented to join the study. Enrolled patients will undergo a high resolution, contrast-enhanced computed tomography angiography (CT) scan of the relevant aortic and aortoiliac vasculature within three months of the scheduled procedure and at specified follow-up intervals post-implantation. Follow-up visits will occur at 30 days, 6 months, and annually to 5 years to assess aneurysm morphology, the status of the implanted devices, and relevant laboratory test results.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Male or female at least 18 years old;
  • Informed consent understood and signed;
  • Patient agrees to all follow-up visits;
  • Have AAA with sac diameter ≥5.0cm, or ≥4.5 cm which has increased by >1.0cm in the past year.
  • Anatomic eligibility for the Nellix System per the instructions for use:
  • Adequate iliac/femoral access compatible with the required delivery systems (diameter ≥6 mm);
  • Aneurysm blood lumen diameter ≤60mm;
  • Most caudal renal artery to aortoiliac bifurcation length ≥100mm;
  • Proximal non-aneurysmal aortic neck: length ≥10mm; lumen diameter 18 to 32mm; angle ≤60° to the aneurysm sac;
  • Common iliac artery lumen diameter between 9 and 35mm with blood lumen diameter ≤35mm;
  • Ability to preserve at least one hypogastric artery.

排除标准

  • Life expectancy <2 years;
  • Psychiatric or other condition that may interfere with the study;
  • Participating in enrollment of another clinical study
  • Known allergy to device any device component;
  • Coagulopathy or uncontrolled bleeding disorder;
  • Ruptured, leaking or mycotic aneurysm;
  • Serum creatinine level >2.0mg/dL;
  • CVA or MI within three months of enrollment/treatment;
  • Aneurysmal disease of the descending thoracic aorta;
  • Clinically significant infrarenal mural thrombus (>5mm thickness over >50% circumference);
  • Connective tissue diseases (e.g., Marfan Syndrome)
  • Unsuitable vascular anatomy;
  • Pregnant (females of childbearing potential only).

结局指标

主要结局

Major Adverse Events at 30 Days

时间窗: 30 days

Major Adverse Events = all-cause death, bowel ischemia, myocardial infarction, paraplegia, renal failure, respiratory failure, stroke, and blood loss \>1,000cc

Treatment Success at 1 Year

时间窗: 1 year

Procedural technical success and the absence of aneurysm rupture, conversion to open surgical repair, Type I endoleak at 12 months, Type III endoleak at 12 months, aneurysm enlargement, secondary procedure for resolution of endoleak (Type I or III), limb occlusion, migration, aneurysm sac expansion and/or a device defect.

次要结局

未报告次要终点

研究者

发起方
Endologix
申办方类型
Industry
责任方
Sponsor

研究点 (60)

Loading locations...

相似试验