Study of the Performance of VCO2 Variation as an Indicator of Fluid Responsiveness in Intensive Care Unit

Hospices Civils de Lyon1 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2022年9月1日最近更新:
适应症

试验速览

阶段
不适用
入组人数
100
试验地点
1
主要终点
The main endpoint is the performance of the variation of the VCO2 (noted ΔVCO2 after obtaining an average before vascular filling VCO2m1 and an average after vascular filling VCO2m2) in ml/min in the detection of fluid-responsiveness.

研究概览

简要总结

The increase of cardiac output resulting from increased blood volume (systolic ejection volume) during intravenous fluid administration defines a state of fluid responsiveness.

Fluid responsiveness in intensive care patients with circulatory failure (shock) needs to be carefully evaluated because only half of the patients are fluid responsive and excessive fluid administration is harmful.

To reliably assess this state, it is currently necessary to perform either invasive cardiac output monitoring or ultrasound evaluation before and after a fluid administration (called fluid challenge). It is either an invasive procedure or a time-consuming technique (that might depend on operator experience and patient echogenicity).

The investigators foresee a potential benefit for an objective quick-answering screening tool that does not require additional monitoring.

Instantaneous CO2 production rate (VCO2) calculated automatically by the most recent ventilators (Hamilton C5-C6) via the analysis of exhaled gases.

There is an established physiological link between cardiac output, arterial oxygen transport to cells and CO2 production by cell metabolism.

The variation in End-Tidal CO2 (another parameter derived from exhaled CO2) is conventionally monitored in the operating room; it can show sudden changes in cardiac output. In intensive care, the EtCO2 variation is probably less sensitive than the variation in VCO2 to detect changes in cardiac output.

The aim of this study is to show that the variation in VCO2 as shown on ventilators during a fluid challenge test has satisfactory diagnostic performance in the detection of fluid responsiveness in patients with circulatory failure in intensive care.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
10 Years 至 —(Child, Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patient hospitalized in intensive care.
  • Patient sedated and mechanically ventilated in Volume Assisted Controlled mode.
  • Patient with hypotension (MAP <65 mmHg OR SAP <90 mmHg) AND / OR under continuous infusion of Norepinephrine / Dobutamine / Epinephrine
  • Patient equipped with a cardiac output measurement system by transpulmonary thermodilution (PICCO®) with a femoral arterial module; as well as a central venous route in the superior or inferior vena cava territory.
  • Exclusion Criteria :
  • Patient under 18 years old
  • Patient under guardianship without the possible consent of the guardian
  • Pregnant woman
  • Pathologies and maneuvers strongly affecting CO2 purification: Diagnosed pulmonary embolism, Prone positioning for less than 60 minutes, Exogenous intake of sodium bicarbonate less than 60 minutes ago (with the exception of an renal replacement therapy in place for more than 60 minutes)
  • Recent change in respiratory quotient: Change in enteral or parenteral nutrition solution for less than 3 hours
  • Pathology affecting CO2 metabolism: Fever> 39 ° c, Intense chills.
  • Patients with unstable ventilation over the hour before inclusion.

排除标准

  • 未提供

结局指标

主要结局

The main endpoint is the performance of the variation of the VCO2 (noted ΔVCO2 after obtaining an average before vascular filling VCO2m1 and an average after vascular filling VCO2m2) in ml/min in the detection of fluid-responsiveness.

时间窗: at the inclusion during less than fifteen minutes

The investigators will analyze the VCO2 variation performance to detect fluid responsiveness as established by the sensitivity, specificity, positive and negative predictive values as well as by analysis of the ROC curve. The Gold Standard used as a comparator for this test is the change in cardiac index (ΔIC in L/min/m2) measured by transpulmonary thermodilution before / after fluid challenge and considered significant if greater than or equal to 10%.