跳至主要内容
临床试验/NCT04300972
NCT04300972已完成不适用

Comparison of Contrast Agent Administration Protocols

Oslo University Hospital0 个研究点目标入组 67 人开始时间: 2016年6月15日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
67
主要终点
CT density of large vessel, measured in Hounsfield units (HU) in the imaging software (PACS)

研究概览

简要总结

The will compare two different ways of administering contrast media in CT exams of the chest:

  1. a fixed dose of contrast medium
  2. a weight- and body-type-adapted dose of contrast medium

The goal is to see if one protocol is superior to the other in reliably producing diagnostic CT images.

详细描述

The continuing advances in computed tomographic (CT) technology in the past decades have provided ongoing opportunities to improve CT image quality, clinical practice and discover new clinical CT imaging applications. New CT technology, however, has introduced new challenges in clinical radiology practice. One of the challenges deals with intravenous contrast medium (CM) administration. Although multidetector CT allows more efficient and flexible use of contrast medium than single-detector CT, to fully reap the benefits of multidetector CT, certain technical challenges involving maximum contrast enhancement and optimal contrast material delivery must be met (1). While CT technology has evolved, the practice of CT intravenous CM administration has been continually debated and updated. The users of new CT technology, accompanied with its newly added technical complexity, discover they fall short of achieving a desired image quality with the traditional standard administration of CM. This entails a change in practice. In the department of Radiology at St Olav University Hospital (SOH), a new protocol for CM administration is now developed and is ready for implementation. This protocol is based on a body weight adapted CM administration, while the current protocol has a fixed CM injection. In this study, this newly CM administration protocol for thoracic CT will be compared to the fixed CM injection protocol. To our knowledge, very few studies (2) have been published on the use of body weight adapted injection protocols for Thoracic CT. Most of the studies report the impact of body weight adapted CM injection protocols for the coronary arteries of CT angiography (3- 5). Therefore, the aim of this study is to determine whether individually tailored protocol(s) for the injection of CM results in higher and more homogeneous vascular attenuation at thoracic CT compared with conventional injection protocols using fixed injection parameters. We know that to achieve optimal contrast enhancement in thoracic CT involves essential factors such as CT tube voltage and CT attenuation, patient factors, CM factors and CT scanning factors (1) and thus all these factors will be addressed and discussed in this investigation.

Specific aims of the study:

  1. To assess and compare the CT attenuation achieved with both protocols
  2. Compare the required amount of CM using weight adapted CM protocol and fixed CM injection protocol
  3. Compare the quality of the images using weight adapted CM protocol and fixed CM injection protocol

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Diagnostic
盲法
Double (Investigator, Outcomes Assessor)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • All patients referred for a thoracic CT (only) at St. Olavs Hospital will be screened for eligibility Inclusion criteria are
  • referral indicates the need for contrast administration (as decided by a radiologist)

排除标准

  • impaired renal function (glomerular filtration rate <60 ml/min)
  • congenital heart disease (as indicated by referral)
  • congestive heart failure (as indicated by referral)

结局指标

主要结局

CT density of large vessel, measured in Hounsfield units (HU) in the imaging software (PACS)

时间窗: immediately after imaging

次要结局

未报告次要终点

研究者

发起方
Oslo University Hospital
申办方类型
Other
责任方
Principal Investigator
主要研究者

Kristian Fosså

MD

Oslo University Hospital

相似试验