Comparison of the Hemodynamic Effects of Phenylephrine and Norepinephrine in Patients Undergoing Deep Inferior Epigastric Perforator (DIEP) Flap Surgery.
试验速览
- 阶段
- 4 期
- 发起方
- 入组人数
- 40
- 试验地点
- 1
- 主要终点
- pulse pressure variation
研究概览
简要总结
Induction of general anesthesia often induces a decrease in the mean arterial blood pressure (MAP) caused by arterial and venous dilatation. Fluid administration is conventionally used to increase the patient's total blood volume, but is often associated with multiple adverse events such as postoperative edema.
Arterial hypotension can also be treated by vasopressor agents such as norepinephrine and phenylephrine which mainly increase the blood pressure by arterial vasoconstriction.
Compared to phenylephrine, norepinephrine has a shorter half-life (2 - 3 minutes) and improves the MAP by increase in cardiac contractility. In a recent study at our department it was demonstrated that besides arterial vasoconstriction, phenylephrine also improves venous return and cardiac output by venous vasoconstriction.
The aim of this study is to compare the hemodynamic effects of both vasopressor agents in patients undergoing deep inferior epigastric perforators (DIEP) flap surgery. If significant differences between both agents are demonstrated, these findings can provide an important basis for future recommendations.
详细描述
In consecutive patients scheduled for DIEP flap surgery, all hemodynamic and respiratory variables are recorded electronically for subsequent off line analysis.
A systolic blood pressure of minimal 100 mmHg will be maintained during surgery by optimization of the cardiac preload and titrated norepinephrine (1.5 µg/kg/h) or phenylephrine (15 µg/kg/h) administration. Cardiac preload optimization will be based on pulse pressure variation (PPV) measurement, which is calculated by pulse contour analysis of the radial arterial pressure curve. Following the international goal-directed fluid therapy guidelines, plasmalyte will be administrated if the PPV>11%.
The tricuspid annular plane systolic excursion (TAPSE) will be measured by transthoracic echocardiography (TTE) to evaluate the inotropic effect of norepinephrine and phenylephrine. In addition, TTE will be used to measure the cardiac output to calibrate the PPV measurements.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Supportive Care
- 盲法
- Triple (Participant, Care Provider, Outcomes Assessor)
入排标准
- 年龄范围
- 18 Years 至 85 Years(Adult, Older Adult)
- 性别
- Female
- 接受健康志愿者
- 否
入选标准
- •patients scheduled for DIEP flap surgery
排除标准
- •unwilling or unable to grant written informed consent
- •contra-indications for phenylephrine or norepinephrine
- •cardiac arrhythmia
- •no necessity for pharmacological blood pressure management
研究组 & 干预措施
phenylephrine
starts at 15 µg/kg/h phenylephrine and titrated to main a minimal systolic blood pressure of 100 mmHg
干预措施: Phenylephrine (Drug)
norepinephrine
starts at 1.5 µg/kg/h phenylephrine and titrated to main a minimal systolic blood pressure of 100 mmHg
干预措施: Norepinephrine (Drug)
结局指标
主要结局
pulse pressure variation
时间窗: perioperative
the evolution of the pulse pressure variation in a time course of 20 minutes after the start of phenylephrine/norepinephrine administration
次要结局
- mean arterial blood pressure(perioperative)
- cardiac output(perioperative)
- stroke volume (variation)(perioperative)
- ventilation frequency(perioperative)
- heart rate(perioperative)
- TAPSE(perioperative)
- end-tidal CO2(perioperative)
- tidal volume(perioperative)
研究者
Dr. Alain Kalmar, MD, PhD
Staff Anesthesist
Algemeen Ziekenhuis Maria Middelares