跳至主要内容
临床试验/NCT02203058
NCT02203058已完成不适用

Pursed-lips Breathing Reduces Reduces Dynamic Hyperinflation Induced by Activities of Daily Living Test in Patients With COPD

University of the State of Santa Catarina2 个研究点 分布在 1 个国家目标入组 25 人开始时间: 2012年3月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
25
试验地点
2
主要终点
Dynamic hyperinflation

研究概览

简要总结

Background: Dynamic hyperinflation (DH) is an important factor leading to dyspnea and consequent limitations in functional capacity of chronic obstructive pulmonary disease (COPD) patients. It has not been completely elucidated whether pursed-lips breathing (PLB) is able to minimize DH and its effects on exercise tolerance in these patients. The aim of this study was to evaluate the acute effect of PLB on DH and functional capacity in patients with COPD.

Design: Randomized cross-over study. Setting: The study will be conducted in an outpatient pulmonary rehabilitation program in Florianópolis, Brazil.

Subjects: Twenty-five patients with COPD (16 men, mean age 64 (7) years, FEV1=41.7 (14.7)% predicted, BMI=27.6 (5.13)kg/m2).

Interventions: Patients will randomly perform two six-minute walk tests with and without PLB (6MWTPLB and 6MWTNon-PLB) and two Glittre-ADL tests with and without PLB (TGlittrePLB and TGlittreNon-PLB).

Main measures: At baseline and immediately after the tests, the inspiratory capacity (IC) will be assessed by the slow vital capacity (SVC) maneuver.

详细描述

Pulmonary function testing Lung function will be tested using an Easy One spirometer (NDD Medical Technologies Inc., Zurich, Switzerland), and calibration checked before each evaluation. Spirometry will be performed in accordance with ATS/ERS standards (Miller et al, 2005). The predicted values will be calculated from the equations proposed by Pereira et al. (2007).

Inspiratory capacity (IC) measurement IC will be measured with the patient in the sitting position, using an Easy One portable spirometer (NDD Medical Technologies Inc., Zurich, Switzerland), before and immediately after the tests, by the slow vital capacity maneuver starting from a stable end-expiratory volume, in accordance with ATS/ERS standards (Miller et al,2005). A minimum of three maneuvers (maximum of eight) will be performed and, in order to be considered reproducible, two curves could not vary by more than 5% or 150mL. The higher value of two reproducible curves will be used for analysis. DH is considered when the IC decreased 10% and/or 150mL or more compared to the basal value (O'Donnell et al, 2001).

Six-minute walk test The 6MWT will be performed according to the guidelines of the American Thoracic Society (2002). Pulse oxygen saturation (SpO2; Oxi-Go, Oximeter Plus, Roslyn Heights, New York, USA) and dyspnea (Borg CR10 scale) will be measured at the beginning and at the end of the test. Predicted values for walking distance will be calculated according to Iwama et al. (2009).

Glittre-ADL test The TGlittre consists of completing a circuit as follows: from a sitting position, the subject stands up and walks along a flat 10-m long course, in the middle of which there is a two-step ladder (each step 17 cm high x 27 cm deep) to be climbed; after completing the 10 m, the subject faces a shelf containing three 1-kg objects positioned on the top shelf (shoulder height) and moves them one by one to the bottom shelf (waist height) and then to the floor; the objects are then returned to the bottom shelf and finally to the top shelf again; the subject walks back, climbing up and down the steps, until reaching the starting point (chair), sits down and immediately begins the next lap. The subjects carry a weighted backpack (2.5 kg for women, 5.0 kg for men) and are instructed to complete five laps on this circuit as quickly as possible. SpO2 and dyspnea index (Borg CR10 scale) will be measured at the beginning of the test, at the end of each lap, and at the end of the test (Skumlien et al, 2006).

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
盲法
None

入排标准

年龄范围
40 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • COPD GOLD stages 2, 3, and 4 of severity of airflow limitation
  • history of smoking ≥ 20 pack-years
  • clinical stability in the four weeks prior to the study protocol

排除标准

  • long-term oxygen therapy
  • current smoking
  • any pulmonary disease other than COPD
  • comorbidities that would compromise their ability to perform any of the evaluations in the study

结局指标

主要结局

Dynamic hyperinflation

时间窗: At the beginning and immediately after de six-minute walk test and Glittre ADL test.

Effect of pursed-lips breathing on inspiratory capacity during the six-minute walk test and Glittre-ADL test.

次要结局

  • Six-minute walk test performance(Both tests (with and without pursed-lips breathing) will be held at least two days to one week apart.)
  • Glittre-ADL test performance(Both tests (with and without pursed-lips breathing) will be held at least two days to one week apart.)

研究者

发起方
University of the State of Santa Catarina
申办方类型
Other
责任方
Principal Investigator
主要研究者

Prof. Dra. Anamaria Fleig Mayer

PhD

University of the State of Santa Catarina

研究点 (2)

Loading locations...

相似试验