跳至主要内容
临床试验/NCT05538221
NCT05538221已完成不适用

Reliability of a Low-cost Video-based Gait Analysis System

Centro Integral de Neurologia y Especialidades Afines, Argentina1 个研究点 分布在 1 个国家目标入组 18 人开始时间: 2022年10月20日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
18
试验地点
1
主要终点
Maximum Ankle angle

研究概览

简要总结

Gait disturbances can be observed in all age groups, and may be due to different conditions, such as advanced age, stroke, head trauma, spinal cord injury, cerebral palsy, myelomeningocele, among others. The aforementioned gait disorders are associated with an increased risk of falls (which can cause major fractures or head trauma), decreased mobility, loss of independence, cardiovascular pathology, and decreased quality of life. In order to improve a given abnormal gait pattern, an objective assessment of gait is necessary. There are several methods to carry out gait evaluations, like Instrumented Gait Analysis (High cost, time-consuming, qualified professionals needed) and the ones based on observation (limited reliability and validity). An alternative, is the use of video-based systems. SILEMA (Computer System for Gait Study Laboratories in Argentina) is a video-based low-cost gait analysis system that measures temporo-spatial (speed, step length, cadence, stance and swing times) and joint kinematic (Hip, Knee, Ankle) parameters. Its reliability has not been reported yet; thus the primary aim of this study is to determine both the "intra-evaluator" (same evaluator, different sessions) and "inter-evaluator" (same session, different evaluators) reliability.

详细描述

Gait disturbances can be observed in all age groups, and may be due to different conditions, such as advanced age, stroke, head trauma, spinal cord injury, cerebral palsy, myelomeningocele, among others. The aforementioned gait disorders are associated with an increased risk of falls (which can cause major fractures or head trauma), decreased mobility, loss of independence, cardiovascular pathology, and decreased quality of life.

One of the main objectives of rehabilitation is the improvement of the gait pattern, for which a correct evaluation of it is a necessary condition. Gait analysis is the systematic study of human locomotion, with joint kinematics (description of movement in different planes) and temporo-spatial parameters (speed, cadence, step length, stance and swing times) being variables usually valued and reported. There are several methods for conducting gait assessments. One of them consists of the administration of scales based on observation, which are accessible and simple to execute, but exhibit limited reliability and validity, depending in addition to the previous experience of the observer. The method considered "Gold standard" is the Instrumented Gait Analysis (IGA), from which parameters of kinematics (through optoelectronic cameras and reflective markers), kinetics (through the use of force platforms) and muscle activity (using electromyography) can be obtained.Unfortunately, these systems are not available in most rehabilitation centers, due to the high cost they represent, the need to have highly trained professionals for their use and the long time needed for calibration and post-processing, difficulties that are continuously mentioned in the literature. An alternative to IGA is the use of video-based systems that allow the quantification of temporo-spatial parameters and joint kinematics. One of these systems is SILEMA(Computer System for Gait Study Laboratories in Argentina) which is based on the technique of digital videography. This system exhibits the advantages of being portable, easy to implement and use, and low cost.The purpose of the clinical analysis of gait is usually to differentiate between normal and abnormal patterns, and to assess the change over time or due to an intervention (surgery, orthosis, botulinum toxin, physical therapy, etc.), being necessary in the latter case to make repeated measurements. Usually, to carry out gait evaluations, the patient is asked to perform several "passes", each of them consisting of a free gait through a walkway, at a "self-selected" speed, during a session in which the corresponding information is collected. In healthy subjects, there is usually a variability between repeated measurements (both intra-subject and inter-subject), which occurs at the expense of intrinsic factors (age, height, gait speed, etc.) or extrinsic, caused by methodological errors (experimental error), such as those related to the placement of markers (task carried out by an evaluator, usually a Therapist, or with the processing of a video made by the operator of the software. The consistency or repeatability of the measurements is what is known as reliability. In other words, reliability is a measure of the variability that exists between repeated measurements, and is usually estimated, as recommended, using the intraclass correlation coefficient "ICC" (Relative Reliability) and the standard error of the measure "SEM" (Absolute Reliability). Its determination is very important, since in daily practice it could give information on whether the observed change in a certain parameter of the gait is due to the intervention / evolution of the pathology or to the variability of the measurements. In the context of gait analysis, reliability is typically evaluated "inter-pass" (between several passes of the same subject, in the same session), "intra-operator" (same video evaluated by the same operator at two different times), "interoperator" (same video, different operators), "intra-evaluator" (same evaluator, different sessions) and "inter-evaluator" (same session, different evaluators). To the best of our knowledge, the reliability of SILEMA has not been reported, being the objective of the present study, to determine this metric, with the intention of expanding its use, both for the clinic and for research.

研究设计

研究类型
Observational
观察模型
Other
时间视角
Cross Sectional

入排标准

年龄范围
18 Years 至 65 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age between 18 and 60 years

排除标准

  • History of any condition (neuromuscular, cardiovascular and/or musculoskeletal) that could generate an atypical gait pattern
  • Pregnancy
  • Known hypersensitivity to adhesive tape

结局指标

主要结局

Maximum Ankle angle

时间窗: One Week

In Degrees. Kinematic parameter to define reliability

Swing Time

时间窗: One Week

Time elapsed between take-off of the toes and the next initial contact of the same foot, expressed in seconds. Kinematic parameter to define reliability

Hip Range of Motion

时间窗: One Week

In Degrees. Kinematic parameter to define reliability

Knee Range of Motion

时间窗: One Week

In Degrees. Kinematic parameter to define reliability

Minimum Knee angle

时间窗: One Week

In Degrees. Kinematic parameter to define reliability

Step Length

时间窗: One Week

Distance between the initial contact of one foot, and the next initial contact of the other foot, expressed in meters. Kinematic parameter to define reliability

Cadence

时间窗: One Week

Number of steps performed on the unit of time. Kinematic parameter to define reliability

Speed

时间窗: One Week

Distance travelled in the unit of time, expressed in meters/seconds .Kinematic parameter to define reliability

Stance Time

时间窗: One Week

Time elapsed between the initial contact of one foot and the take-off of the toes of the same foot, expressed in seconds.Kinematic parameter to define reliability

Maximum Hip angle

时间窗: One Week

In Degrees. Kinematic parameter to define reliability

Minimum Hip angle

时间窗: One Week

In Degrees. Kinematic parameter to define reliability

Minimum Ankle angle

时间窗: One Week

In Degrees. Kinematic parameter to define reliability

Ankle Range of Motion

时间窗: One Week

In Degrees. Kinematic parameter to define reliability

Maximum Knee angle

时间窗: One Week

In Degrees. Kinematic parameter to define reliability

次要结局

未报告次要终点

研究者

发起方
Centro Integral de Neurologia y Especialidades Afines, Argentina
申办方类型
Other
责任方
Principal Investigator
主要研究者

Bernardo Centeno

Medical Doctor

Centro Integral de Neurologia y Especialidades Afines, Argentina

研究点 (1)