Surgical Aortic Valve Replacement: IMPACT of Pre-existing Comorbidities on Patient Outcomes and Prosthetic Valve Performance in a Real-world Setting.
试验速览
- 阶段
- 不适用
- 状态
- 进行中(未招募)
- 发起方
- 入组人数
- 500
- 试验地点
- 34
- 主要终点
- All-cause mortality
研究概览
简要总结
The IMPACT Registry represents a non-interventional, prospective, open-label, multicenter, international registry with a follow-up of 5 years that includes data of patients undergoing aortic valve replacement with the Edwards INSPIRIS RESILIA Aortic Valve™. The IMPACT Registry will be performed in up to 25 participating sites across Germany, Austria and Switzerland. A minimum number of 500 patients (20 patients per center) will be enrolled. Patients will undergo follow-up visits at baseline, surgery, pre-discharge, year 1, year 3 and year 5.
详细描述
The INSPIRIS RESILIA Aortic Valve™ is a stented tri-leaflet valve comprised of bovine pericardial tissue. The tissue is created by treating bovine pericardial tissue with Edwards Integrity Preservation. It incorporates a stable capping anticalcification process, which blocks residual aldehyde groups known to bind with calcium. Tissue preservation with glycerol allows the valve to be stored without a traditional liquid-based solution, such as glutaraldehyde. Therefore, valve is stored under dry packaging conditions and consequently does not require rinsing prior to implantation.
The novel tissue preservation technology significantly improves hemodynamic and anticalcification properties compared with the standard Perimount valve in an ovine model (Flameng et al., 2015). The RESILIA tissue has been studied in the COMMENCE trial: Two year data show that the NYHA class improved in 65.7% of patients, effective orifice area after implantation was 1.6 ± 0.5 cm2; mean gradient was 10.1 ± 4.3 mmHg; and paravalvular leak was none/trivial in 94.5% of patients (mild to moderate in 0.5%) (Puskas et al., 2017).
On the sizes 19 - 25 mm the INSPIRIS RESILIA Aortic Valve™ has been outfitted with the VFit technology, which incorporates two novel features designed for potential future valve-in-valve procedures: fluoroscopically visible size markers and an expandable cobalt chromium alloy band. No clinical data are available that evaluate the use of the INSPIRIS RESILIA Aortic Valve™ in patients to date.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patient is at least 18 years old
- •Patient has an aortic valve vitium and requires an aortic valve replacement with the Edwards INSPIRIS RESILIA Aortic Valve™
- •Patient is scheduled to attend yearly follow-up visits at the registry center up to 5 years
- •Patient provides written informed consent prior to the procedure and in case of emergency after the procedure.
排除标准
- •Disability and / or other circumstances under which the patient is not capable to understand the nature, significance and scope of the clinical trial
- •Active endocarditis/myocarditis or endocarditis/myocarditis within 3 months prior to the scheduled aortic valve replacement surgery
- •Patient has a life expectancy ≤ 12 months for any reason
- •Valve implantation is not possible in accordance with the device IFU
结局指标
主要结局
All-cause mortality
时间窗: after 5 years
All-cause mortality after 5 years will be investigated
All-cause mortality
时间窗: after 1 year
All-cause mortality after 1 year will be investigated
All-cause mortality
时间窗: after 3 years
All-cause mortality after 3 years will be investigated
次要结局
- Mortality(after 5 years)
- Mortality(after 1 year)
- Mortality(after 3 years)