跳至主要内容
临床试验/NCT04804592
NCT04804592已完成不适用

Investigation in Variability and Repeatability of Corneal Sensation in a Normal Population and Contact Lens Wearers

Daniela Nosch1 个研究点 分布在 1 个国家目标入组 111 人开始时间: 2021年5月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
111
试验地点
1
主要终点
Repeatability of mechanical corneal sensation thresholds with the liquid jet protoype esthesiometer

研究概览

简要总结

The aim is to find out more about how corneal sensory fibres react to different types of stimuli (liquid / tactile / nylon thread) and how this can be consciously perceived by the individual. Is it possible to generate a stimulus that delivers a repeatable and reliable response within a useful stimulus force range which allows an interpretation / evaluation of normal / expected activity of superficial nerve fibres in the cornea? The study group will be divided into three groups of individuals: two groups with different types of contact lenses (CL) and one without CL, as sensitivity changes are thought to occur with CL wear. A very interesting research question is to find out, if such sensitivity differences can be detected with the nature of the stimuli applied in this study.

详细描述

The aim of this study is to gain more physiological knowledge about ocular surface sensation (corneal sensitivity), with application of three different concepts employing different types of stimuli for triggering a response from the pain sensitive nerve endings in the superficial cornea: 1) tactile method: a round plastic nozzle (2 mm diameter) is applied to the ocular surface with a defined, low force for a duration of 100ms. 2) liquid jet method: a liquid jet (isotonic saline) of a temperature to match ocular surface temperature is applied to the ocular surface with low pressure and low volume, from a distance of 15 mm.3) commercially available Cochet Bonnet esthesiometer (nylon thread). The study group will be divided into three groups of individuals: two groups with different types of contact lenses (CL) and one without CL, as sensitivity changes are thought to occur with CL wear. A very interesting research question is to find out, if such sensitivity differences can be detected with the nature of the stimuli applied in this study.

Current knowledge about human corneal sensitivity is limited, as applied methods for ocular surface sensation measurement are limited with regards to reproducibility / accuracy.

Corneal sensitivity represents a neurological response from the free nerve endings within the epithelium. They are sensitive to mechanical, electrical, chemical or thermal stimuli and hence have a protective function for the cornea. Corneal nerves play an important role in cell growth and proliferation of epithelial cells, wound healing and repair. In experimental studies, corneal denervation has been reported to result in epithelial changes: increased permeability, decreased proliferation, changed appearance and delayed wound healing. Therefore, intact corneal innervation is required to maintain the integrity of a normal corneal epithelium. Corneal sensory nerves are believed to play an important role in maintaining the resting tear flow, as their afferent impulses from the ocular surface lead to a reflex response, best described by the lacrimal functional unit: an integrated system comprising the ocular surface tissues (cornea, corneal limbus, conjunctiva, conjunctival blood vessels, and eyelids), the tear secreting components (main and accessory lacrimal glands, meibomian glands, conjunctival goblet, and epithelial cells), and the sensory and motor nerves that connect them.

Current knowledge about ocular surface sensitivity is insufficient, as currently available measurement possibilities lack repeatability and accuracy. Before a new instrument can be developed, more research is required, in order to find a suitable concept for precise sensitivity measurement. For this purpose, two new different concepts with different / new stimulus types will be applied repeatably on healthy eyes in this study. The aim is to find out more about how corneal sensory fibres react to different types of stimuli (liquid / tactile / nylon thread) and how this can be consciously perceived by the individual. Is it possible to generate a stimulus that delivers a repeatable and reliable response within a useful stimulus force range which allows an interpretation / evaluation of normal / expected activity of superficial nerve fibres in the cornea? The study group will be divided into three groups of individuals: two groups with different types of contact lenses (CL) and one without CL, as sensitivity changes are thought to occur with CL wear.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Parallel
主要目的
Basic Science
盲法
None

入排标准

年龄范围
18 Years 至 50 Years(Adult)
性别
All
接受健康志愿者
是

入选标准

  • •Silicone hydrogel (SiHy) CL wear at least 3 days per week and at least 8 hours per day; 18 - 50 years of age; healthy eyes with OSDI </= 13
  • •Rigid gas permeable (RGP) CL wear at least 3 days per week and at least 8 hours per day; 18 - 50 years of age; healthy eyes with OSDI </= 13
  • •No current CL wear for at least 3 months; 18 - 50 years of age; healthy eyes with OSDI </= 13

排除标准

  • •Systemic disease that may affect ocular health, such as diabetes
  • •Injury and history of operations on the anterior segment of the eye
  • •regular application of systemic or ocular medication known to affect the tear film, specifically on the day of measurement

研究组 & 干预措施

Group A: SiHy CL

Experimental

Silicone hydrogel (SiHy) CL wear at least 3 days per week and at least 8 hours per day;

干预措施: Tactile Esthesiometer Prototype (Device)

Group A: SiHy CL

Experimental

Silicone hydrogel (SiHy) CL wear at least 3 days per week and at least 8 hours per day;

干预措施: Liquid Jet Esthesiometer Prototype (Device)

Group A: SiHy CL

Experimental

Silicone hydrogel (SiHy) CL wear at least 3 days per week and at least 8 hours per day;

干预措施: Cochet Bonnet esthesiometer (Device)

Group B: RGP CL

Experimental

Rigid gas permeable (RGP) CL wear at least 3 days per week and at least 8 hours per day;

干预措施: Tactile Esthesiometer Prototype (Device)

Group B: RGP CL

Experimental

Rigid gas permeable (RGP) CL wear at least 3 days per week and at least 8 hours per day;

干预措施: Liquid Jet Esthesiometer Prototype (Device)

Group B: RGP CL

Experimental

Rigid gas permeable (RGP) CL wear at least 3 days per week and at least 8 hours per day;

干预措施: Cochet Bonnet esthesiometer (Device)

Group C: no CL wear

Experimental

No current CL wear for at least 3 months;

干预措施: Tactile Esthesiometer Prototype (Device)

Group C: no CL wear

Experimental

No current CL wear for at least 3 months;

干预措施: Liquid Jet Esthesiometer Prototype (Device)

Group C: no CL wear

Experimental

No current CL wear for at least 3 months;

干预措施: Cochet Bonnet esthesiometer (Device)

结局指标

主要结局

Repeatability of mechanical corneal sensation thresholds with the liquid jet protoype esthesiometer

时间窗: two weeks

Evaluation of repeatability of mechanical corneal sensation thresholds for the measurement with the liquid jet esthesiometer prototype instrument (in mbar): the corneal sensation thresholds will be obtained with the double staircase method (with forced choice) and the stimulus represents a liquid jet (consisting of isotonic saline solution).

Repeatability of mechanical corneal sensation thresholds with the tactile prototype esthesiometer

时间窗: two weeks

Evaluation of variability / repeatability of mechanical corneal sensation thresholds for the measurement with the tactile esthesiometer prototype instrument (in mN): the corneal sensation thresholds will be obtained with the double staircase method (with forced choice) and the stimulus represents a small, round plastic ball.

Repeatability of mechanical corneal sensation thresholds with the Cochet Bonnet esthesiometer

时间窗: two weeks

Evaluation of repeatability of mechanical corneal sensation thresholds for the measurement with the Cochet Bonnet instrument (in mN): the corneal sensation thresholds will be obtained with the double staircase method (with forced choice) and the stimulus represents a nylon thread, whereby its force is proportional to the length of the nylon thread applied to the corneal surface.

次要结局

  • Correlation between corneal sensation thresholds with the tactile prototype esthesiometer(one day)
  • Comparison of corneal sensation thresholds, obtained with the Cochet Bonnet esthesiometer, between the three groups in the study population(two weeks)
  • Comparison of corneal sensation thresholds, obtained with the liquid jet prototype esthesiometer, between the three groups in the study population(two weeks)
  • Comparison of corneal sensation thresholds, obtained with the tactile prototype esthesiometer, between the three groups in the study population(two weeks)
  • Correlation between corneal sensation thresholds with the Cochet Bonnet esthesiometer(one day)
  • Correlation between corneal sensation thresholds with the liquid jet prototype esthesiometer(one day)

研究者

发起方
Daniela Nosch
申办方类型
Other
责任方
Sponsor Investigator
主要研究者

Daniela Nosch

Professor

University of Applied Sciences and Arts Northwestern Switzerland

研究点 (1)

Loading locations...

相似试验