跳至主要内容
临床试验/NCT02751671
NCT02751671已完成不适用

Are Stimulated Clean-Catch Urine Collection Techniques More Successful When Combined With Prior Emergency Point-of-care Ultrasound in Paediatric Patients?

St. Justine's Hospital2 个研究点 分布在 1 个国家目标入组 201 人开始时间: 2016年8月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
201
试验地点
2
主要终点
Successful clean-catch manoeuver

研究概览

简要总结

Background:

The investigators recently evaluated a new bladder stimulation technique to obtain clean-catch urine in infants aged less than six months. In this study, the reported success rate was of 52%. Measuring the transversal bladder diameter prior to the procedure with emergency point-of-care ultrasound (ePOCUS) could likely increase success rates for this technique as it has been described for bladder scans prior to performing urethral catheterization.

Objective:

The aim of this study is to evaluate if using emergency point-of-care ultrasound to measure bladder volume improves clean-catch urine collection success in patients less than 6 months of age when compared to children undergoing this technique without a prior ultrasound.

Methods:

This will be a randomized controlled trial performed in a tertiary paediatric emergency department. Participants will include all infants younger than 6 months of age who need a urinary culture and/or analysis requested by the attending physician. The intervention will consist of the use of emergency point-of-care ultrasound by a trained research assistant. The primary outcome will be the rate of success of the procedure. Secondary objectives will be to evaluate time to collect urine samples and to determine which transversal bladder diameter correlates with more than a 90% success rate for the procedure. Independent variables will be sex and age. In both groups, trained research nurses will collect clean-catch urine samples using bladder stimulation techniques. The success rate of the CCU procedure in both groups will be calculated. The time required to collect urine samples will be analysed. In group 1, the investigators will determine the transversal bladder diameter corresponding to a success rate for the procedure of > 80%. It is estimated that, in the worse-case scenario, the evaluation of 200 participants will provide a 95% confidence interval smaller than 10% for proportions. In addition, 20 participants with a successful CCU sample would allow to evaluate 2 risk factors using univariate and multivariate analysis.

Expected results:

This study will demonstrate that use of emergency point-of-care ultrasound increases success rates of stimulated clean-catch manoeuvres and may avoid invasive urethral catheterizations in young children.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
— 至 5 Months(Child)
性别
All
接受健康志愿者

入选标准

  • Children aged less than 6 months
  • Urine sample ordered by the treating physician
  • Presence of a research assistant

排除标准

  • Any medical condition where obtaining a midstream urine sample is impossible (e.g. urostomy, anuria for 24h)
  • Any serious illness or unstable infant (e.g. sepsis)
  • Any medical situation where the infant cannot be fed (e.g NPO order, GCS<15)
  • Inability to obtain parental informed consent (language barrier, absence, etc.)

研究组 & 干预措施

POCUS before clean catch sampling

Experimental

The intervention of interest will be the use of emergency point-of-care ultrasound performed by a research assistant to evaluate bladder fullness before clean-catch stimulation manoeuvre. More specifically, following randomisation, children in the experimental group will have ePOCUS to measure the transversal bladder diameter. If the transversal bladder diameter is > 2 cm, the CCU procedure will be started without a prior feeding period. If the diameter is < 2 cm, the CCU will be postponed for a 20 minute feeding period and a new ePOCUS will be done. After the second ePOCUS, the CCU will be done if the transversal bladder diameter reaches > 2cm. If not, the child will have another 20 minute feeding period and a third ePOCUS prior to proceeding to the CCU regardless the bladder diameter.

干预措施: POCUS (Procedure)

Standard clean catch sampling

Experimental

Patients allocated to this arm will have a 20 minute feeding period either being breastfed or provided with formula intake appropriate to the infant's age and weight. If possible, the genital areas of the infant will be cleaned with warm water and soap and dried with sterile gauze prior to the feeding. The parents will let the diaper opened and will be will be ready to collect urine if the child voids during the feeding period. After the feeding, the stimulated clean-catch procedure will be performed without prior ultrasound

干预措施: Standard (Procedure)

结局指标

主要结局

Successful clean-catch manoeuver

时间窗: 5 minutes

The rate of successful clean-catch urine sample collection. Success is defined by the collection of a sample of urine of at least 2 mL, obtained within 300 seconds of bladder stimulation manoeuvers or obtained while disinfecting prior to the manoeuvre.

次要结局

  • Delay for collection(1 hour)
  • delay for procedure(1 hour)
  • Nurse time(2 hours)

研究者

发起方
St. Justine's Hospital
申办方类型
Other
责任方
Principal Investigator
主要研究者

Jocelyn Gravel

MD

St. Justine's Hospital

研究点 (2)

Loading locations...

相似试验

Point-of-care Ultrasound for Clean-Catch Urine... | 临床试验