Difference in Postoperative Total Wavefront Pattern Between Aspheric and Negative Spherical Aberration Intraocular Lenses Implanted in Cataract Surgery

Cairo University1 个研究点 分布在 1 个国家目标入组 40 人开始时间: 2020年11月9日最近更新:
适应症
干预措施

试验速览

阶段
不适用
入组人数
40
试验地点
1
主要终点
Corneal, Ocular, and Internal spherical aberrations

研究概览

简要总结

With the advancement of cataract eye surgery and wavefront sensors, the previously unquantifiable refractive measurements have been identified and the high order aberrations have shown their effect on high resolution imaging.

In the human phakic eye, the shape of the normal cornea induces average positive spherical aberration and remains unchanged over time, whereas the crystalline lens has a negative spherical aberration. As a result, overall spherical aberration in the young eye is low.

However, the compensation slowly decreases with the aging lens and is fully lost after cataract extraction and implantation of a standard intraocular lens.

Optical studies showed that conventional biconvex spherical intraocular lenses add their intrinsic positive spherical aberration to the positive spherical aberration of the cornea resulting in image imperfection and blur. As a useful side effect, this also increases the depth of focus -often referred to as pseudo-accommodation.

New Aspheric intraocular lenses designs currently in use impart negative spherical aberration, about 0.17 to 0.20 microns of negative spherical aberration. This added negative spherical aberration partially corrects the average amount of corneal positive spherical aberration & compensate for its effect. Our study will include (FocusForce foldable aspheric intraocular lens, Bausch & Lomb, New Jersey, USA) as an example of this type of negative spherical aberration intraocular lenses.

In order to improve retinal image quality without compromising depth of field, or introducing other aberrations, aberration-free aspheric intraocular lenses were developed with no inherent spherical aberration.

The other intraocular lens targeted in our study (Akreos AO Microincision lens, Bausch & Lomb, New Jersey, USA) is an example of this type of IOLs.

详细描述

A customized correction for the individual eye seems to be the most promising solution for tailored correction of spherical aberration.

On the other hand, Wave front analysis of the ocular optical system has increased our knowledge of the aberrations in the eye. The importance of measuring optical aberrations lies not only in the presence of natural aberrations in the human eye, but also in its usefulness for evaluating individual surgical outcomes. By using Zernike polynomials, the aberrations of the ocular system can be characterized. Zernike coefficients of the higher-order aberrations can be derived from corneal topographic data. And for those generated by the whole optical system of the eye can be derived from aberrometry.

With current small-incision cataract surgery, it has been reported that the average postoperative corneal topography does not differ significantly from average preoperative corneal topography, so in our study we will focus on the ocular & internal wave front changes.

With the high resolution pyramid wavefront sensor incorporated in (SCHWIND PERAMIS®, topography and Aberrometry, Kleinostheim, Germany) we will evaluate and compare the total ocular wave front and the corneal wave front in our study to identify and estimate the internal aberrations . This new sensor uses an extended source instead of a point-like source avoiding in this manner the oscillation of the pyramid.

SCHWIND PERAMIS evaluates the ocular wave front aberrations with 45,000 measuring points - without any overlap and with clear assignment of each point & records 33 images per second and automatically selects the image with the best measurement. Together with real-time measurement, this ensures a new level of detail resolution and precision. SCHWIND PERAMIS can also be used to compare a patient's corneal and ocular wave front data. The direct comparison provides information about whether a visual defect is located on the surface of the cornea or within the eye itself, thus allowing us to identify and evaluate internal aberrations.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
21 Years 至 75 Years(Adult, Older Adult)
性别
All
接受健康志愿者
是

入选标准

  • •1-All patients with written informed consent, between the age of 21 -75 years who will undergo phacoemulsification procedure with intraocular lens implantation of one of the targeted lenses in the study

排除标准

  • •Previous corneal intervention or refractive surgery.
  • •Persistent Corneal edema (epithelial or stromal).
  • •Co-existing corneal pathology.
  • •Ocular surface disease & Dry eye syndrome.
  • •Posterior capsular opacity .
  • •Anterior capsular contraction (phimosis).
  • •Ocular inflammation.
  • •Co-existing Vitreoretinal diseases.

研究组 & 干预措施

aberration-free IOL

Experimental

20 human eyes with aberration-free intraocular lens Implantation after phacoemulsification cataract surgery

干预措施: phacoemulsification with intraocular lens implantation (Procedure)

aberration-free IOL

Experimental

20 human eyes with aberration-free intraocular lens Implantation after phacoemulsification cataract surgery

干预措施: ocular aberrometer assesment (Device)

negative spherical aberration IOL

Active Comparator

20 human eyes with negative spherical aberration intraocular lens Implantation after phacoemulsification cataract surgery

干预措施: phacoemulsification with intraocular lens implantation (Procedure)

negative spherical aberration IOL

Active Comparator

20 human eyes with negative spherical aberration intraocular lens Implantation after phacoemulsification cataract surgery

干预措施: ocular aberrometer assesment (Device)

结局指标

主要结局

Corneal, Ocular, and Internal spherical aberrations

时间窗: 1 month postoperative

assessment of ocular, corneal \& internal wavefront by aberrometer \& corneal tomography

次要结局

  • corneal wavefront changes(1 month postoperative)
  • near vision addition(1 month postoperative)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Aya Ghonaim

resident of ophthalmology

Cairo University

研究点 (1)

Loading locations...