跳至主要内容
临床试验/NCT04084899
NCT04084899已完成不适用

The Effect of Continuous Positive Airway Pressure Therapy on Lung Hyperinflation in Patients With Obstructive Sleep Apnoea

University Hospital Olomouc1 个研究点 分布在 1 个国家目标入组 50 人开始时间: 2019年9月5日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
50
试验地点
1
主要终点
Change of Vital Capacity (VC) (ml)

研究概览

简要总结

Assessment of the lung hyperinflation by bodypletysmography in patients with obstructive sleep apnoea treated with continuous positive airway pressure therapy.

详细描述

Rationale:

Obstructive sleep apnoea (OSA) is characterized by repetitive closure of upper airways leading to apnoea (complete airflow cessation) or hypopnoea (airflow limitation > 50% + blood oxygen desaturation > 3% or airflow limitation > 30% blood oxygen desaturation > 4%). The prevalence of lung hyperinflations in sleep apnoea patients and effect of continuous positive airway pressure (CPAP) therapy is not known.

Process:

Subjects included in the study will be obstructive sleep apnoea (OSA) patients diagnosed by respiratory polysomnography performed in the Sleep Laboratory, Department of Respiratory Medicine, University Hospital Olomouc.

Bodypletysmography will be performed in the time of OSA diagnosis and after 3 months of CPAP therapy.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Obstructive sleep apnoea syndrome indicated for CPAP therapy (Apnoea- Hypopnoea index ˃ 15)

排除标准

  • - Bilevel positive airway pressure therapy
  • Total lung capacity < 80% lower limit of normal values
  • Obstructive ventilatory disorder
  • Change in body weight ˃ 10%
  • Change in smoking status

结局指标

主要结局

Change of Vital Capacity (VC) (ml)

时间窗: 3 months

Percentage change of Vital Capacity after 3 months of CPAP therapy.

Change of Forced Expiratory Volume in 1 second (FEV1) (ml)

时间窗: 3 months

Percentage change of Forced Expiratory Volume in 1 second after 3 months of CPAP therapy.

Change of Total Lung Capacity (TLC) (ml)

时间窗: 3 months

Percentage change of Total Lung Capacity after 3 months of CPAP therapy.

Change of Residual Volume (RV) (ml)

时间窗: 3 months

Percentage change of Residual Volume after 3 months of CPAP therapy.

次要结局

未报告次要终点

研究者

发起方
University Hospital Olomouc
申办方类型
Other
责任方
Principal Investigator
主要研究者

Milan Sova

Principal Investigator, Head of Sleep Laboratory, Department of Respiratory Medicine

University Hospital Olomouc

研究点 (1)

Loading locations...

相似试验

The Effect of CPAP on Lung Hyperinflation in... | 临床试验