Validation of Measurement of Cardiac Output With LiDCO Rapid and TEE (Trans Esophageal Echocardiography) by Comparing With Intermittent Thermodilution Technique in Cardiac Surgical Patients

University of Iowa1 个研究点 分布在 1 个国家目标入组 110 人开始时间: 2012年10月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
110
试验地点
1
主要终点
The primary objective of the study is measured cardiac output by LiDCO Rapid is as equivalent ( within 30%) as measured by pulmonary artery catheter using intermittent thermodilution method among patients undergoing elective cardiac surgery.

研究概览

简要总结

Measurement of the cardiac output is one of the important hemodynamic monitoring tools in cardiac surgery. It helps determine the type of medications needed to maintain optimal hemodynamic status in the entire perioperative period. Thermodilution method using pulmonary artery catheter is considered has the gold standard for the measurement of cardiac output. Investigators would like to compare the most popular minimally-invasive devices used to measure cardiac output using arterial waveform: LiDCO Rapid and TEE with the thermodilution method at various phases of the cardiac surgery.

详细描述

Measurement of the cardiac output is one of the important hemodynamic monitoring tools in cardiac surgery. It helps determine the type of medications needed to maintain optimal hemodynamic status in the entire perioperative period. Thermodilution method using pulmonary artery catheter is considered has the gold standard for the measurement of cardiac output, however over the past 10 to 15 years it has been questioned about its safety and efficacy. There has been a surge in recent years of less invasive devices capable of measuring cardiac output by various means, including bioimpedance, transpulmonary thermodilution, transthoracic and transesophageal echocardiography, and arterial waveform analysis.

There is a variety of devices currently available for cardiac output measurement by arterial-waveform analysis. These devices have been compared to each other, and to the pulmonary artery catheter as the gold standard. However, the companies manufacturing these devices have made software upgrades that they believe improves their performance. No studies have been performed comparing the uncalibrated arterial waveform based cardiac output measurement device,LiDCORapid since the software upgrades. In addition to baseline cardiac output measurements, Investigators intend to study the effect of volume loading (by trendelenburg position), sympathetic stimulus (incision), a vasodilated state (15 minutes after separation from CPB) and chest closure on cardiac output measured by the three different techniques.

In addition to cardiac output the investigators would like to measure stroke volume ,Systemic Vascular Resistance, stroke volume variation with LiDCO . The main purpose is to validate the accuracy of measurements by these two minimally-invasive methods in comparison with thermodilution method in various hemodynamic states.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
30 Years 至 90 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Elective cardiac procedures other than those specified in the exclusion criteria

排除标准

  • All emergency cardiac procedures, prisoners and pregnant women, patients who are scheduled for ventricular assist devices and those with severe aortic, mitral and tricuspid insufficiency will be excluded.

结局指标

主要结局

The primary objective of the study is measured cardiac output by LiDCO Rapid is as equivalent ( within 30%) as measured by pulmonary artery catheter using intermittent thermodilution method among patients undergoing elective cardiac surgery.

时间窗: During intraoperative period.

次要结局

  • The secondary objective of the study is measured cardiac output by TEE using VTI at LVOT is as equivalent ( within 30%) as measured by pulmonary artery catheter using intermittent thermodilution method among patients undergoing elective cardiac surgery.(During intraoperative period)