NCT00779948已完成不适用
Dynamic Internal Fixation of Femoral Neck Fractures
适应症
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- Aesculap AG
- 入组人数
- 171
- 试验地点
- 9
- 主要终点
- Cumulative Complication Rate
研究概览
简要总结
Evaluation of dynamic Plate-Screw-Systems for internal fixation after femoral neck fractures. Open Registry for Comparison of 1-screw-systems (DHS) with multi-screw-system Targon FN.
详细描述
Two implant systems are mainly used for internal fixation: canulated screws and plate-screw-systems. Regarding the latter, the dynamic hip screw systems (DHS)represent the most frequently used devices.
Targon FN (Aesculap) is a new plate-screw system and available on the market since 2007. In contrast to the DHS, which uses only one telescrew, the Targon FN provides up to four telescrews.
With this registry, we want to evaluate the results of Targon FN compared with DHS systems.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 55 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •men >= 60 years, women >= 55 years
- •femoral neck fractures needing surgical therapy
- •femoral head preserving indication
- •Living in a 100 km Radius from Hospital
排除标准
- •Patient not able to walk
- •Previous fracture or surgery on ipsilateral hip
- •pathological fracture
- •open fracture
结局指标
主要结局
Cumulative Complication Rate
时间窗: 1 year
次要结局
- Course of Surgery Mobilization Radiology functional Results (SF-12, IOWA Hip Score)(1 year)
研究者
研究点 (9)
Loading locations...
相似试验
Unknown
不适用
Intracapsular Femoral Neck Fractures Fixation With a Dynamic Locking Plate and Screw System, Targon FNFemoral Neck FracturesNCT00830687Sheba Medical Center100
已完成
不适用
Plate Fixation of Distal Femur Fractures: A Protocol for a Study of Two Plate OptionsFemoral FracturesNCT00644397MetroHealth Medical Center80
已完成
不适用
Mid-Term Radiological Outcomes of Femoral Neck Fractures Treated With Osteosynthesis: A Comparative AnalysisFemoral Neck FracturesFemoral Neck ShorteningNCT06263309Istanbul University10
已完成
不适用
Comparison of Clinical Efficacy Between Dynamic Dip Screw and Cannulated Compression Screw for Fresh Femoral Neck FractureFemoral Neck FracturesNCT04959370Peking University Third Hospital91
招募中
4 期
Clinical outcomes of femoral neck fracture fixation: Femoral neck system versus Cannulated screws, A randomized control trialFemoral neck fracture patient requiring surgical fixationHip fracture, Femoral neck fracture, Femoral neck system, Cannulated screwsTCTR20230116002Rajavithi hospital28