Evaluation of Half-Dose Molecular Breast Imaging With Wide Beam Reconstruction Processing
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- Mayo Clinic
- 入组人数
- 83
- 试验地点
- 2
- 主要终点
- Compare the Diagnostic Accuracy of 8 mCi Molecular Breast Imaging (MBI) With 4 mCi MBI.
研究概览
简要总结
The primary objective of this work is to determine if half-dose Molecular Breast Imaging (MBI) performed with 4 mCi Tc-99m sestamibi with or without Wide Beam Reconstruction applied can achieve image quality and diagnostic accuracy non-inferior to that of standard MBI performed with 8 millicurie (mCi) Tc-99m sestamibi.
详细描述
Recent implementation of dose reduction strategies for Molecular Breast Imaging now allow performance of MBI at an administered dose of 8 mCi Tc-99m sestamibi, which is reduced from the previously used doses of 20-30 mCi. In order to safely introduce MBI as a screening modality, we aim to perform MBI using 4 mCi Tc-99m sestamibi. An image processing algorithm called Wide Beam Reconstruction (WBR) has been tailored for MBI technology with the goal of allowing either the current administered dose or current acquisition time to be reduced by half.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 40 Years 至 —(Adult, Older Adult)
- 性别
- Female
- 接受健康志愿者
- 是
入选标准
- •Subgroup 1, Patients with breast lesions:
- •At least one breast lesion detected by mammogram, ultrasound or breast MRI that measures < 20 mm in greatest dimension, presents as a mass, is considered suspicious or highly suggestive of malignancy according to the Breast Imaging Reporting and Data System Atlas criteria (BIRADS 4 or 5), and is scheduled for core-needle biopsy or surgical biopsy.
- •At least one breast lesion that measures between > 10 mm but < 20 mm in greatest dimension, presents as a mass, is biopsy-proven as malignant, and is scheduled for surgical resection.
- •Age > 40 years
- •Negative pregnancy test, postmenopausal, or surgically sterilized
- •Subgroup 2, Patients without known breast lesions:
- •Negative screening mammogram performed at Mayo Clinic Rochester within 15 months prior to performance of study MBI
- •No signs or symptoms of breast disease
- •Age > 40 years
- •Negative pregnancy test, postmenopausal, or surgically sterilized
排除标准
- •Vacuum-assisted or excisional biopsy has been performed prior to the study MBI. Reason: these types of biopsies are more likely to remove all of the tumor
- •MBI is performed after biopsy and neo-adjuvant chemotherapy is planned prior to surgery. Reason: true tumor size will not be able to be ascertained from the final pathology findings
- •Breast implants. Reason: cases with breast implants will be easily identifiable on blinded interpretation to take place at the study end
- •Suspected that breasts will not fit in the MBI field of view. Reason: cases that require tiled views or additional views will be easily identifiable on blinded interpretation to take place at the study end
- •Only one breast remaining. Reason: unilateral cases will be easily identifiable on blinded interpretation to take place at the study end; injection timing is designed for bilateral views
- •Pregnancy test (if necessary) is not negative, or the patient is unable to complete the pregnancy test
- •Physically unable to sit upright and still remain still during two consecutive MBI studies over the course of a 2-hour period.
研究组 & 干预措施
Molecular breast imaging
Molecular Breast Imaging at 4 mCi dose and at 8 mCi dose, consecutively.
干预措施: Molecular breast imaging (Diagnostic Test)
结局指标
主要结局
Compare the Diagnostic Accuracy of 8 mCi Molecular Breast Imaging (MBI) With 4 mCi MBI.
时间窗: At time of study (within 2 days after exam) and when enrollment has been reached (approximately 24 months)
次要结局
未报告次要终点
研究者
Carrie Hruska
Prinicipal Investigator
Mayo Clinic