跳至主要内容
临床试验/NCT05613257
NCT05613257已完成不适用

A Randomized Controlled Trial Comparing Free-Hand Versus Distal Targeting Jig-Based for Distal Interlock Screw Placement

Cedars-Sinai Medical Center2 个研究点 分布在 1 个国家目标入组 89 人开始时间: 2022年10月31日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
89
试验地点
2
主要终点
Patient Radiation Exposure

研究概览

简要总结

This study is a randomized controlled trial comparing the use of two different surgical techniques--free-hand versus distal targeting jig-based for distal interlock screw--placement and their effects on total operative time and intraoperative radiation exposure.

详细描述

Interlocking screw placement in intramedullary nailing of femoral and tibial shaft fractures improves rotational and length stability. However, free-hand perfect circle techniques can be technically challenging and may take up to an hour with increased radiation exposure to the surgeon and patient. Newer technologies aimed at reducing fluoroscope use such as electromagnetically-based aiming devices may increase the operative time. Proximally-based jigs have been shown to reduce fluoroscopy time in cadavers, however, have not been studied clinically. This study is a prospective, randomized controlled trial comparing a modern proximally-based distal targeting device and free-hand techniques for placement of interlocking screws in lower extremity nailing.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Participant)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • 18 years old and above
  • Undergoing intramedullary fixation of femur or tibia shaft for acute fracture or nonunion

排除标准

  • Prior ipsilateral tibial or femoral nail
  • Patients who cannot have interlocking screws placed
  • Pregnant women

结局指标

主要结局

Patient Radiation Exposure

时间窗: During surgery: The first fluoroscopy shot for distal interlocking screw placement to final fluoroscopy shot confirming the final screw's placement

Number of fluoroscopic images taken intraoperatively for screw placement and cumulative radiation exposure (in grays)

Total Screw Placement Time

时间窗: During surgery: the first fluoroscopy shot to localize the jig or obtain a perfect circle (start) to the last shot to confirm complete seating of the screw (end time)

time taken to place interlocking screws

Measurement of Screw Placement Angle

时间窗: Intraoperatively (at end of surgery)

Correct screw placement is at a right (90-degree) angle from the intramedullary nail, through the interlocking screw hole

Amount of Cumulative Radiation Exposure (in Grays)

时间窗: During surgery: The first fluoroscopy shot for distal interlocking screw placement to final fluoroscopy shot confirming the final screw's placement

Total radiation exposure during distal screw placement

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Carol A. Lin, MD

Assistant Professor

Cedars-Sinai Medical Center

研究点 (2)

Loading locations...

相似试验