The Evaluation of the Relationship Between Thicknesses and Isokinetic Strength of Hip Flexor and Extensor Muscles in Patients With Unilateral Traumatic Transfemoral Amputation
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 发起方
- 入组人数
- 27
- 试验地点
- 1
- 主要终点
- 10-meter walking test
研究概览
简要总结
The aim of this study is to investigate the relationship of hip muscle thicknesses measured by ultrasonography with hip flexion and extension strength and clinical parameters in prosthesis users with unilateral traumatic transfemoral amputation.
详细描述
The aim of this study is to investigate the relationship of hip muscle thicknesses measured by ultrasonography with hip flexion and extension strength and clinical parameters in prosthesis users with unilateral traumatic transfemoral amputation.
This study will be useful in understanding whether ultrasonography is an appropriate imaging method in the follow-up of changes in functional strength in the hip girdle in patients with unilateral traumatic transfemoral amputation.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Only
- 时间视角
- Cross Sectional
入排标准
- 年龄范围
- 18 Years 至 65 Years(Adult, Older Adult)
- 性别
- Male
- 接受健康志愿者
- 否
入选标准
- •Aged between 18-65
- •The time elapsed after amputation > 6 months
- •Using prosthesis for at least 3 months
- •Being able to walk without an assistive device
排除标准
- •Bilateral lower extremity amputation
- •Presence of neurological, cardiovascular, and pulmonary disease that may affect walking performance
结局指标
主要结局
10-meter walking test
时间窗: through study completion, an average of one month
The short-distance over-ground gait speed will be assessed using a 10-Meter Walk Test. Participants will be asked to walk at normal pace on a 10-meter walkway.
Timed up and go test
时间窗: through study completion, an average of one month
Timed up and go test will be used for quantifying functional mobility balance. Participants will be instructed to sit in a comfortable position on a 45-65 cm high steady chair with a backrest and armrest, with both arms resting on their thighs, and then quickly stand up and move towards and around a fixed cone 3 m away, return, and sit again.
6-minute walking test (6MWT)
时间窗: through study completion, an average of one month
Functional performance will be assessed by 6MWT (in meter). Patients will be instructed to walk quickly, safely, and as much distance as possible over a rectangular path.
次要结局
未报告次要终点
研究者
Yasin Demir
Associate professor
Gaziler Physical Medicine and Rehabilitation Education and Research Hospital
