跳至主要内容
临床试验/NCT06544824
NCT06544824进行中(未招募)不适用

Accuracy of Markerless Motion Analysis in Comparison With Optoelectronic Motion Capture System

IRCCS Eugenio Medea1 个研究点 分布在 1 个国家目标入组 25 人开始时间: 2024年5月15日最近更新:
适应症

试验速览

阶段
不适用
状态
进行中(未招募)
发起方
入组人数
25
试验地点
1
主要终点
Absolute Error

研究概览

简要总结

The purpose of this study was to assess the Openpose reliability to measure kinematics and spatiotemporal gait parameters and to evaluate the minimum technical requirements. This analysis used video and optoelectronic motion capture simultaneously recorded. We assessed more of 20 subject with different motor gait impairments

详细描述

Marker-based Optical motion tracking is the gold standard in gait analysis, but today, markerless solutions are growing rapidly. Treatment of physical impairments could improve if supported with reliable motion capture. Moreover, the use of markerless technology offers numerous advantages for working with pediatric populations under various conditions. In this paper, we assess the Openpose reliability to measure kinematics and spatiotemporal gait parameters and to evaluate the minimum technical requirements., in a population of children with and without gait impairments. Validating markerless methods can open the way for new motion capture techniques and enhance the accessibility of kinematic measurements and improve the treatment of physical impairments.

研究设计

研究类型
Observational
观察模型
Other
时间视角
Retrospective

入排标准

年龄范围
4 Years 至 65 Years(Child, Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age over 4 years;
  • Ability to walk independently without walking aids and/or orthoses.

排除标准

  • Inability to walk independently and safely for short distances without walking aids and/or orthoses.

结局指标

主要结局

Absolute Error

时间窗: Through study completion, an average of 1 year

Absolute errors were calculated for the kinematics parameters and for each spatiotemporal variable by taking the absolute value after subtracting the values obtained using pose estimation methods from the value measured using markerbased motion capture

intraclass correlation coefficients

时间窗: Through study completion, an average of 1 year

To confirm whether the data obtained by OpenPose agreed with the data from the optoelectronic system, investigators calculated the ICCs (two-way mixed effects model, absolute agreement, average measurements) between the spatiotemporal and kinematic data from both systems. The ICC values were interpreted as follows: poor agreement for ICC \< 0.5, moderate agreement for values between 0.5 and 0.75, good agreement for values between 0.75 and 0.9, and excellent agreement for values greater than 0.90.

cross-correlation coefficients

时间窗: Through study completion, an average of 1 year

The cross-correlation coefficients (CCC) between both systems were used to evaluate the similarity of angles during the gait cycle. The CCC values were interpreted as follows: weak or no coupling for values between -0.3 and 0.3, moderate coupling for values between 0.3 and 0.7 or -0.7 and -0.3, and strong coupling for values greater than 0.7 or less than -0.7.

次要结局

未报告次要终点

研究者

发起方
IRCCS Eugenio Medea
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...