Patient Satiety as an Indicator of Stomach Contents and Fluid Volume: an Observational Prospective Study

Imeldaziekenhuis1 个研究点 分布在 1 个国家目标入组 501 人开始时间: 2021年6月5日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
501
试验地点
1
主要终点
the correlation between total gastric fluid volume in millilitres and a ten-point (0-10) satiety scale.

研究概览

简要总结

This research proposal aims to investigate the correlation between a) the hunger feeling as measured by a ten point scale and b) total gastric fluid volumes and content as measured with gastric PoCUS in fasted, healthy subjects > 18 of age, scheduled for elective surgery.

详细描述

An ultrasound exam will be performed before induction of anaesthesia. GUS results from selected patients will be systematically acquired and assessed following an algorithm (Appendix Ia). The ultrasound results will be collected on a standardized form (Appendix IIa). The technique is performed in the supine and right lateral decubitus position (Appendix Ib) and only by anesthesiologists with sufficient experience with ultrasound and the technique. The patient will be asked to indicate his/her satiety on a predetermined ten-point scale. Patient data and satiety score will be collected on a standardized form (Appendix IIb). The scanning anaesthesiologist is blinded to the result of the questionnaire.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 85 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • - Age ≥ 18 years
  • Fasted according to national guidelines
  • Elective surgery
  • ASA physical status I-II
  • Ability to assume both supine and right lateral decubitus position.
  • Able to understand and to sign informed consent

排除标准

  • - Previous esophagus and gastric surgery, hiatal hernia, gastric cancer.
  • Pregnancy
  • Failure of GUS (defined as failure to visualize the antrum)

结局指标

主要结局

the correlation between total gastric fluid volume in millilitres and a ten-point (0-10) satiety scale.

时间窗: Before surgery

total gastric fluid volumes are measured with gastric point-of-care ultrasound, satiety is measured with a 0 to 10 scale. Zero stands for no satiety ( very hungry, thirsty), ten stands for fully satisfied ( no hunger or thirst).

次要结局

  • the correlation between the type of gastric content ( no content, fluid content, solid content) and a ten-point (0-10) satiety scale(before surgery)
  • the correlation between the Perlas grading scale ( 0,1,2) and a ten-point (0-10) satiety scale.(Before surgery)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Peter Van de Putte

Principal investigator, MD PhD

Imeldaziekenhuis

研究点 (1)

Loading locations...