临床试验/NCT03251742
NCT03251742已完成1 期

Feasibility and Efficacy Of Negative Pressure Ventilation in Fontan populatioN: Cardiovascular Flow Assessment by Magnetic Resonance Imaging

University Health Network, Toronto2 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2017年11月17日最近更新:
适应症
干预措施

试验速览

阶段
1 期
状态
已完成
入组人数
20
试验地点
2
主要终点
Efficacy of the NPV on cardiac output

研究概览

简要总结

The human heart has 4 chambers: 2 collecting chambers (atria) and 2 pumping chambers (ventricles) to allow blood flow within two distinct circuits: "pulmonary" and "systemic". The pulmonary circuit directs the blood to the lungs to receive oxygen and the systemic circuit delivers oxygen-rich blood throughout the body. In children born with a single ventricle, blood from these two circuits mixes within the heart resulting in lower oxygen levels in the blood delivered to the body (cyanosis).

The Fontan procedure is a palliative surgery which bypasses the need for a ventricle to deliver blood to the lungs, as blood from the body flows passively to the lungs by a man-made connection (whereby two large body veins [cavae] are sewn to the pulmonary arteries), thereby preventing mixing of blood through restoration of two distinct circuits without mixing of blood. Although the Fontan operation effectively eliminates cyanosis and enables survival into adulthood, increased systemic venous pressure is an unavoidable systemic complication and low cardiac output (CO) is pervasive finding.

Despite excellent pediatric surgical results, the risk of late complications and death dramatically increases in the decades following Fontan surgery. A chronically low CO state secondary to decreased forward flow of blood to the lungs can result in end-organ dysfunction and shortened life expectancy. Short of heart transplantation, deemed suitable only for a minority of patients, effective therapies for low CO are largely absent. The investigators aim to investigate a novel, non-invasive, ambulatory therapy which can augment CO. Specifically, external suction is applied intermittently to the chest wall, much like a vacuum, to increase CO, called negative pressure ventilation (NPV) using a Cuirass® ventilator (Hayek Medical). Although used in patients with lung disease, the investigators' proposal is to evaluate this novel, portable, ventilation system would be the first study of its kind in adults with congenital heart disease, specifically those with a Fontan palliation.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Parallel
主要目的
Other
盲法
None

入排标准

年龄范围
13 Years 至 55 Years(Child, Adult)
性别
All
接受健康志愿者

入选标准

  • Fontan patients age > 13 years.

排除标准

  • unable to complete MRI (pacemaker/defibrillator/retained wires, pregnancy, claustrophobia);
  • evidence of Fontan failure (requiring ongoing medical / device therapy) protein-losing enteropathy, intracardiac thrombus, anatomical obstruction to the Fontan circuit;
  • patent Fontan fenestration;
  • oxygen saturation < 90%;
  • ongoing arrhythmia;
  • ejection fraction < 50% on echocardiography or CMR;
  • moderate or severe valve insufficiency on echocardiography or CMR;
  • Obesity (BMI >35);
  • severe obstructive sleep apnea (AHI>20);
  • chronic obstructive lung disease (FEV1/FVC<60%);
  • severe chest wall deformities (scoliosis, kyphosis, kyphoscoliosis);
  • acute or chronic kidney disease (eGFR<60)
  • unable to provide informed consent.

研究组 & 干预措施

Healthy volunteers

Sham Comparator

干预措施: Hayek RTX ventilator (Device)

Fontan patient population

Active Comparator

干预措施: Hayek RTX ventilator (Device)

结局指标

主要结局

Efficacy of the NPV on cardiac output

时间窗: 6-8 months

Cardiac output will be measured in L/min/m2 using phase contrast MRI. Flow measurements will be made at baseline and with application of the device.

Efficacy of the NPV on organ perfusion

时间窗: 6-8 months

Multi organ perfusion will be measured in L/min/m2 using phase contrast MRI. Flow measurements will be made at baseline and with application of the device.

次要结局

  • Tolerability and safety of negative pressure ventilation.(6-8 months)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Pradeepkumar Charla

Clinical Fellow

University Health Network, Toronto