Clinical Evaluation of a Multipurpose CZT Camera in Gated Tomographic Radionuclide Angiography: a Head to Head Comparison With a Cardiac Dedicated CZT Device
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 73
- 试验地点
- 2
- 主要终点
- Assessment of left and right ventricular volumes and ejection fraction.
研究概览
简要总结
Tomographic radionuclide angiography (or blood pool) is a reproducible method to evaluate left ventricular ejection fraction that is needed during oncological treatments or to evaluate cardiopathies.
Cardiac-dedicated CZT systems allowed dose or time reduction. Multipurpose CZT cameras have not yet been evaluated in this indication. Moreover, the impact of attenuation correction is not known.
详细描述
Tomographic radionuclide angiography is a simple, rapid and reproducible method of cardiac function measurement, including left (LVEF) and right (RVEF) ventricular ejection fractions.
In addition to cardiological indications, this examination is often performed as part of cardiac toxicity screening during the various oncological treatments. This indication is all the more true since the arrival of CZT gamma cameras dedicated to cardiological studies has made it possible to reduce injected activities, as well as examination times.
The multipurpose CZT camera allows tomoscintigraphic acquisitions to be carried out using CZT technology as well. Unlike the CZT gamma cameras dedicated to cardiological studies, this system can be used for the exploration of different organs, and also allows the realization of CT slices for attenuation correction.
Patients included in this study will be double scanned both on a dedicated cardiac CZT camera and on multipurpose CZT camera, with CT. LVEF and RVEF will be then compared.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Other
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients referred to our Nuclear Medicine department for evaluation of cardiac function.
排除标准
- •Patients treated with chemotherapy within 12 days.
- •Under 18 years old patients.
- •Pregnant women or at risk of pregnancy.
- •Breast feeding.
- •Painful patients.
- •Patients under guardianship.
- •Patients in whom a standard examination is not feasible (agitation).
- •Patients who do not benefit from a social security system
结局指标
主要结局
Assessment of left and right ventricular volumes and ejection fraction.
时间窗: Day 0
Automatic quantification of left and right ventricular volumes, left ventricle ejection fraction (LVEF) and right ventricle ejection fraction (RVEF) using BPGs software (Cedars-Sinai Medical Center, Los Angeles, USA).
次要结局
- Assessment of left and ventricular volumes and ejection fraction with attenuation correction.(Day 0)