A Comparison of Rapid Immunoassay Tests for the Detection of Ruptured Membranes
试验速览
- 阶段
- 不适用
- 状态
- 撤回
- 试验地点
- 1
- 主要终点
- This study is designed to determine number of participants with rupture of membranes from clinical assessment.
研究概览
简要总结
Specific objectives include analysis of performance of ROM Plus® in diagnosing ROM, as compared to Amnisure® and the conventional clinical assessment confirmed by a thorough chart review after delivery.
详细描述
Premature rupture of membranes (PROM), defined as spontaneous rupture of membranes (ROM) before the onset of uterine contractions, is one of the most common diagnostic dilemmas in contemporary obstetric practice. Premature rupture of membranes can occur at any gestational age, and preterm PROM (PPROM, defined as PROM before 37 weeks) is responsible for 20-40% of preterm births. Early and accurate diagnosis of PROM would allow for gestational age-specific obstetric interventions designed to optimize perinatal outcome and minimize serious complications such as cord prolapse, preterm delivery, fetal distress and infectious morbidity (chorioamnionitis, neonatal sepsis). Conversely, a false-positive diagnosis of PROM may lead to unnecessary obstetric interventions, including hospitalization, administration of antibiotics and corticosteroids, and even induction of labor. Therefore, the correct and timely diagnosis of this disorder is of critical importance to the clinician because PROM and PPROM may be associated with serious maternal and neonatal consequences.
The diagnosis of fetal membrane rupture is conventionally made using a clinical assessment. First, by speculum examination, the clinician looks for amniotic fluid leaking from the cervical os. If clear fluid is visualized leaking from the cervical os, the diagnosis is positive for fetal membrane rupture. More commonly, leaking is absent, and a more extensive workup is required, which includes nitrazine/pH testing, visual inspection of pooling of fluid in the posterior fornix, and a microscopic evaluation of the collected specimen (ferning). Although this approach is considered the standard of care, it is fraught with inaccuracies, requires an intrusive examination and may not provide a rapid diagnosis.
Rapid, point of care, qualitative immunochromatographic tests (ie., Amnisure®, ActimProm®, Amnioquick®) that detect proteins found in amniotic fluid at high concentrations, have been used to diagnose the rupture of membranes (ROM) for several years. In many hospitals, Amnisure® has replaced the sterile speculum exam as the standard of care for diagnosing ROM. It identifies Placental Alpha Microglobulin-1 (PAMG-1), a 34 kd fetal glycoprotein, in cervicovaginal secretions.
Recently a new, rapid, point of care, qualitative immunochromatographic test was introduced to the market, ROM Plus®. Unlike the other immunoassay tests, ROM Plus® uses a unique monoclonal/polyclonal antibody approach to detect two different proteins found in amniotic fluid at high concentrations. ROM Plus® detects Placental Protein-12 (also known as Insulin-like Growth Factor Binding Protein-1) as well as Alpha Fetoprotein (AFP). The combination of PP12 and AFP were chosen not only because of their robust historical literature support as ideal protein markers for amniotic fluid5-22, but also their unique characteristics. PP12 is synthesized by the decidua of the placenta and reaches a very high concentration level in the amniotic fluid early in the first trimester and stays at that level until delivery. However, AFP, synthesized by the fetal liver and yolk sac, reaches its peak concentration late in the second trimester/early third trimester. This increases the chance that the proteins will be detected, especially in the preterm patients, when the diagnosis of ROM is most crucial.
This study is designed to assess the performance (sensitivity, specificity, PPV, NPV) of ROM Plus® and Amnisure®.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 性别
- Female
- 接受健康志愿者
- 是
入选标准
- •Any woman who presents with alleged leakage of amniotic fluid is eligible for recruitment
排除标准
- •Known placental previa
- •Active vaginal bleeding
结局指标
主要结局
This study is designed to determine number of participants with rupture of membranes from clinical assessment.
时间窗: From hospital presentation on complaint of leaking fluid to delivery estimated to be less than 30 days. (up to 30 days)
The standard of care is to perform a sterile speculum exam and noting the evidence of leakage of fluid from the cervical os, and if necessary, pooling of fluid in the posterior fornix, assessing the fluid with nitrazine/pH and ferning under the microscope. The following chart review criteria will be assessed: Major Criteria * the results of the initial SSE (leaking, pooling, ferning, nitrazine) and any follow-up SSE * the AFI using ultrasound assessment * the number of hours from the initial exam to delivery (\<48 hours will be considered suggestive of ROM) * evidence of chorioamnionitis and/or endomyometritis
次要结局
- Results of AmniSure test.(From hospital presentation on complaint of leaking fluid to delivery estimated to be less than 30 days. (up to 30 days))
- Results of ROM PLus Test(From hospital presentation on complaint of leaking fluid to delivery estimated to be less than 30 days. (up to 30 days))
研究者
Professor Hemantha M. Senanayake
Professor, Department of Obstetrics and Gynaecology