跳至主要内容
临床试验/NCT03728998
NCT03728998已完成不适用

Can Non-invasive Measurement of Cardiac Index, Stroke Volume and Systemic Vascular Resistance Contribute to Better Tailoring of Treatment in Patients Presenting With Sepsis to the ED?

Medical Centre Leeuwarden1 个研究点 分布在 1 个国家目标入组 31 人开始时间: 2018年5月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
31
试验地点
1
主要终点
The percentage of subjects in whom a passive leg raise test resulted in a 15% or more improvement in cardiac index measured by the Clearsight non-invasive hemodynamic monitoring system.

研究概览

简要总结

Little is known about the optimal fluid therapy of patients with uncomplicated sepsis. Most recommendations are extrapolated from studies performed in patients with septic shock. Therefore, it is unknown how effective our current fluid therapy is. Furthermore, current therapy is not tailored to individual needs. The aim of the current study is to investigate the added value of non-invasive measurements of (dynamic) circulatory parameters in the treatment of a convenience sample of sepsis patients presenting to the ED.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Screening
盲法
None

入排标准

年龄范围
16 Years 至 —(Child, Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • At presentation in the ED:
  • there has to be evidence of an infection: -temp <36 or >38 without an obvious cause for hypo-or hyperthermia
  • There has to be evidence of organ dysfunction by the presence of at least one of the following criteria: altered mental state, hypoxia (spo2<94% or 5% lower than baseline), lactate >2 mmol/l in ABGA or VBGA directly drawn after presentation, hypotension (MAP<65 mmHg or SBP<100mmHg), or a respiratory rate>22/min.

排除标准

  • Patients with septic shock (i.e. who remained hypotensive after fluid bolus administration, needing vasopressor therapy to obtain a MAP>65 in the presence of a lactate >
  • (i.e. septic shock) These will be excluded afterwards, but will be shown in an inclusion flowchart.
  • Subjects for whom it is impossible to obtain a reliable signal for Clearsight measurements.
  • Increased abdominal pressures
  • Need for immediate ventilatory support or surgery
  • Presence of an acute cerebral event, acute coronary syndrome, acute pulmonary edema, status asthmaticus, active gastrointestinal bleed, trauma
  • Known metastatic cancer
  • Pregnancy

研究组 & 干预措施

PLR & Clearsight measurements

Other

All patients 16years or older presenting to the ED with uncomplicated sepsis (see inclusion and exclusion criteria) will undergo a Passive Leg Raise (PLR, non-invasive) and multiple measurements by the Clearsight non-invasive hemodynamic monitoring system. Followed by a fluid challenge (common practice; non interventional)

干预措施: Passive leg raise (PLR) (Other)

PLR & Clearsight measurements

Other

All patients 16years or older presenting to the ED with uncomplicated sepsis (see inclusion and exclusion criteria) will undergo a Passive Leg Raise (PLR, non-invasive) and multiple measurements by the Clearsight non-invasive hemodynamic monitoring system. Followed by a fluid challenge (common practice; non interventional)

干预措施: Clearsight non-invasive hemodynamic monitoring system (Other)

结局指标

主要结局

The percentage of subjects in whom a passive leg raise test resulted in a 15% or more improvement in cardiac index measured by the Clearsight non-invasive hemodynamic monitoring system.

时间窗: 1 hour

3 baseline readings will be done for CI separated by one minute intervals. Subsequently, the standardized passive leg-raise test will be performed and measurements of CI will be repeated at 30, 60, 90 and 120 seconds. Then the patient is repositioned to his original position, and after two minutes another reading of CI is done. A difference of 15% or more is found to be clinically significant.

次要结局

  • The ability of non-invasively measured baseline CO, CI, SVR and SV to predict fluid-responsiveness correctly (measurements by the Clearsight non-invasive hemodynamic monitoring system).(1 hour)