跳至主要内容
临床试验/NCT03952247
NCT03952247已完成不适用

Prospective, Randomized Study in Ventilated Critically Ill Patients Receiving Percutaneous Tracheotomy. A Comparison of Periinterventional Visualization of Conventional Bronchoscopy and Single Use Bronchoscopy (TraSUB™)

Universitätsklinikum Hamburg-Eppendorf1 个研究点 分布在 1 个国家目标入组 46 人开始时间: 2019年5月15日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
46
试验地点
1
主要终点
Visualisation

研究概览

简要总结

Optical guidance for percutaneous tracheostomy in intensive care is usually performed by conventional multi use bronchoscopy. Recently a single use bronchoscope has been introduced that allows for endotracheal visualization.

For feasibility evaluation, 23 patients in intensive care receive percutaneous tracheostomy with optical guidance by the Ambu® aScopeTM 4 bronchoscope and 23 patients in intensive care receive percutaneous tracheostomy with a conventional bronchoscope (Olympus BF Type P60). The primary end point is the visualization through the single use bronchoscope of endotracheal landmark structures for tracheostomy and visualization of the needle insertion (according to score, see detailed description).

详细描述

Background Long-term ventilated critically ill patients often receive a tracheostomy to facilitate weaning from the ventilator and for prevention of secondary complications by the endotracheal tube. Besides surgical tracheostomy in which a muco-cutaneous fistula is prepared between trachea and outer skin, percutaneous tracheostomy (PDT) has been introduced, in which a cannula is being inserted into the trachea. After introduction of a guidewire, the trachea is then dilated. This intervention should be led by optical guidance, i. e. to verify the correct point of tracheal cannulation between the 2nd and 3rd tracheal cartilage and to minimize the risk for accidental injury to the membranous part of the trachea. Usually, optical guidance is performed by conventional multi use bronchoscopy. During bronchoscopy in ventilated patients, a drop in minute ventilation or an increase of carbon dioxide partial pressure with a consecutive respiratory acidosis may occur. Recently, a single use bronchoscope has been introduced that permits a continuous visualisation of the trachea on a monitor connected to the camera (Ambu® aScopeTM 4, Ambu, Ballerup, Denmark) . In this study, it is being evaluated whether the optical guidance during PDT can be performed by the Ambu® aScope 4. The advantage of a single use bronchoscope for percutaneous dilatative tracheostomy in comparison to a conventional reuseable bronchoscope is that there is no need for repair or decontamination after use.

Methods:

Design of Study/ No. of Patients:

Randomized, prospective study/ 46 patients With a sample size of 46 (randomized 1:1 in 2 groups of 23 each) a difference of 35% on a visualization score [6] may be seen with an α-error of 0,05 and a β-error of 1-0,8.

Procedures:

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Patients receiving percutaneous tracheotomy in the Dept. of Intensive Care Medicine.
  • •Age ≥ 18 years
  • •Informed consent

排除标准

  • •Age < 18 years
  • •No consent
  • •Direct laryngoscopy according to Cormack-Lehane ≥ 3

研究组 & 干预措施

Single Use Bronchoscopy

Experimental

optical guidance of percutaneous tracheotomy is done by single use bronchoscopy

干预措施: Single Use Bronchoscopy for PDT (Device)

Conventional Multi Use Bronchoscopy

Active Comparator

optical guidance of percutaneous tracheotomy is done by conventional multi use bronchoscopy

干预措施: Conventional Multi Use Bronchoscopy for PDT (Device)

结局指标

主要结局

Visualisation

时间窗: during tracheotomy

visualisation through the single use bronchoscope of endotracheal landmark structures for tracheotomy and visualization of the needle insertion (according to score) Scale Name: Rating A) Identification of: thyroid cartilage, cricoid cartilage, 1st-3rd tracheal cartilage 1 Reliable identification; 2 Only cricoid cartilage and tracheal cartilages; 3 Only tracheal cartilages; 4 No vision on tracheal structures B) Visualization of tracheal circumference 1 Complete; 2 circumference 1/3 to 2/3 of circumference; 3 Only small parts of trachea; 4 No vision on tracheal structures C) Monitoring puncture: midline + level below 1st or 2nd tracheal cartilage 1 Reliable identification; 2 Midline sure Level uncertain, but below the 1st tracheal cartilage; 3 Level of puncture uncertain; 4 No vision on tracheal structures D) Monitoring dilatation Anterior wall and Pars membranacea (P.m.) visible; 1 Reliable identification; 2 P.m. only; 3 Only small parts of trachea visible, no control of P.

次要结局

  • Poor control(during tracheotomy)
  • pH(three time points: baseline value (before sterile drapes are applied), 0 min before skin incision, and 0 min after insertion of tracheal cannula)
  • adverse events(up to 1 week)
  • paO2(three time points: baseline value (before sterile drapes are applied), 0 min before skin incision, and 0 min after insertion of tracheal cannula)
  • paCO2(three time points: baseline value (before sterile drapes are applied), 0 min before skin incision, and 0 min after insertion of tracheal cannula)
  • etCO2(three time points: baseline value (before sterile drapes are applied), 0 min before skin incision, and 0 min after insertion of tracheal cannula)
  • Minute ventilation(two time points: 1. during identification of landmark structures before puncture of trachea, 2. during puncture, dilatation and tracheotomy)
  • Poor visualisation(during tracheotomy)
  • Peak airway pressure(three time points: baseline value (before sterile drapes are applied), 0 min before skin incision, and 0 min after insertion of tracheal cannula)
  • Duration of intervention(during tracheotomy (skin incision till insertion of tracheal cannula))

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验