临床试验/NCT03268486
NCT03268486Unknown不适用

Evaluation of a Novel Signal Acquisition Technique for Intrapartum Cardiotocography

University of Lisbon0 个研究点目标入组 50 人开始时间: 2017年10月1日最近更新:
适应症

试验速览

阶段
不适用
入组人数
50
主要终点
Signal quality

研究概览

简要总结

Cardiotocography (CTG) is widely used during labour wards in industrialised countries and consists of fetal heart rate and uterine contraction monitoring. The main aim is to identify fetuses that are being poorly oxygenated during labour and require medical intervention to revert the situation or expedite delivery.

The need for technical development of CTG is well-recognized, as some of the existing techniques are prone to signal loss and contamination from the maternal heart rate, while others are invasive and have established contra-indications. They also limit maternal mobilisation, contributing to maternal dissatisfaction, and possibly to adverse maternal and neonatal outcomes.

New techniques for CTG acquisition will shortly be made available by a leading technological company, providing non-invasive monitoring and allowing full maternal mobilisation, and with the potential to change the way labour is conducted in high-resource countries. There is a need for a systematic evaluation of their clinical performance and benefit.

详细描述

First phase of the study will start in October 2017 in labor wards at Hospital de Santa Maria, Lisbon where performing continuous cardiotocographic fetal monitoring with conventional Doppler technology is the routine procedure. Through a collaboration with Phillips (Boeblingen, Germany) we will have access to a transabdominal ECG/EHG recorder that has high accuracy/reliability and Bluetooth technology providing mobility and and more comfort for mothers. This new device works through five disposable electrodes that are positioned on the maternal abdomen in a standardized manner: one electrode is placed near the umbilicus, a second is placed above the symphysis pubis in a vertical line from the umbilicus, a third and a fourth are placed on opposite sides of the abdomen horizontal to the umbilicus; the ground is placed on the upper right side. Women will be informed of the study by posters and leaflets distributed during the antenatal period and on arrival at labor wards. The inclusion criteria are singleton term pregnancies, spontaneous or induced/augmented labor, cephalic presentation, > 18 years of age, able to provide written informed consent, no contraindications to internal FHR monitoring and no known contraindication to vaginal delivery. Patients with risk factors for intrapartum hypoxia will also be included. After giving written informed consent, women will be simultaneously monitored with scalp electrode, Doppler, trans-abdominal ECG, abdominal EHG and TOCO, as soon as internal monitoring is possible. The maternal abdominal skin will be prepared for low impedance by gentle excoriation of the surface skin cells. Monitoring will be maintained until as close to delivery as possible, and the three FHR signals will be conveyed to a computer acquisition storage system for offline analysis. We aim a sample size of 100 participants. EHG and TOCO will be compared for signal loss, contraction frequency, and contraction area. Transabdominal ECG and Doppler will be compared in terms of signal loss, and with internal ECG regarding signal accuracy. The signal quality will be analysed separately for each monitoring method for the time during which the FHR recorded. As the two FHR modalities do not share a common time clock, synchronisation should be achieved by cross correlating the two heart rate files and locating the peak correlation. The clinical management of labour will be uniquely on the basis of external Doppler ultrasound CTG recordings. Both signals will also be compared for coincidences with MHR determined by maternal ECG with FHR determined by internal ECG. The abdominal fECG monitor calculates the MHR as well as the FHR simultaneously. It uses the height and the width of the QRS complex, both of which are linked to the size of the heart, to differentiate between the fetal and maternal heart signals. Women will be encouraged to perform a sequence of standardized exercises, in the presence of the investigator, and the periods when the mother is lying down, sitting, standing and walking will be recorded.

A subgroup analysis will be performed in the different stages of labour, particularly during maternal pushing, as well as in women with different skin colour and body mass index categories and in the different positions they adopt. Both umbilical cord arterial and venous blood sampling will be performed for the diagnosis of newborn metabolic acidosis, as soon as possible after birth. Data on basic demographic characteristics, pregnancy complications, course of labor, and neonatal outcome will be obtained.

In the second phase of the study, we want to know if the different traces acquired from the same fetus through transabdominal ECG and Doppler CTG may have different interpretations and may lead to different obstetric attitudes. In order to do that we will retrospectively analyze all the independent traces through a computer analysis (Omniview-SisPorto program). This system emits visual and sound alerts when features associated with poor fetal oxygenation are detected and has been shown to provide analysis that is in good agreement with a consensus of experts. The main outcome will be the agreement of alerts displayed by each signal acquisition technique regarding the same fetus.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
Female
接受健康志愿者

入选标准

  • Singleton term pregnancies, spontaneous or induced/augmented labor, cephalic presentation, > 18 years of age, able to provide written informed consent, no contraindications to internal FHR monitoring and no known contraindication to vaginal delivery. Patients with risk factors for intrapartum hypoxia will also be included.

排除标准

  • Do not give a written consent.

结局指标

主要结局

Signal quality

时间窗: The analysis will be made at the end of the recruiting phase (that will have 3 months of duration)

Transabdominal ECG and Doppler will be compared in terms of signal loss, and with internal ECG regarding signal accuracy. The signal quality will be analysed separately for each monitoring method for the time during which the FHR recorded.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Ana Catarina Reis de Carvalho

Resident

University of Lisbon