跳至主要内容
临床试验/NCT06832579
NCT06832579已完成不适用

Pilot Study for SmartWatch-driven AF Detection in Stroke Patients

University of Leipzig26 个研究点 分布在 1 个国家目标入组 84 人开始时间: 2025年5月15日最近更新:
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
84
试验地点
26
主要终点
sensitivity as a function of AF duration

研究概览

简要总结

Unrecognized atrial fibrillation (AF) is a common cause of ischemic stroke. Implantable event monitors (ICM) are the gold standard for continuous heart rhythm monitoring but they have been implemented in very few patients after stroke due to high invasiveness and high costs.

In this trial, patients with implanted ICMs (Medtronic Reveal LINQ Insertable Cardiac Monitor) will be randomized to use one of two wearables (1:1 Apple Watch or PulseOn) for continuous monitoring. The aim is to compare the probability of detecting an episode of AF with a wearable versus the gold standard ICM.

Both groups will use the wearable for 12 weeks. If the wearables detect an arrhythmic pulse curve, this is communicated by vibration. By laying the other hand on the device, a 1-channel ECG is performed. ECG data will be transferred regularly to the CoreLab (Universityhospital Leipzig) for analysis.

After 12 weeks, the patients will visit the site and answer questions regarding the usability, compliance and satisfaction with the wearables.

详细描述

Patients with established continuous ICM monitoring from the prospective, randomized, multicenter study Find-AF 2 (NCT04371055) are recruited for this trial. Find-AF 2 is being carried out at Leipzig University Hospital since 2020 with the help of about 50 study centers throughout Germany.

The AppleWatch Series 10, a device from the current market leader, was chosen because extensive data from clinical trials is already available and data regarding the market leader has particular societal relevance. The AF detection algorithm is based on photoplethysmography (analysis of the pulse current curve) and semicontinuous monitoring. If a rhythm irregularity is detected during hourly measurements, the measurement interval is shortened. If this finding is confirmed in several consecutive measurements, the user is notified. In this pilot study, patients are trained to record a 30-second ECG with the AppleWatch in the event of notification. This is done by placing the other hand on the crown of the watch. The report will then be transmitted. The AppleWatch must be paired with another Apple device (e.g. iPhone) to use the ECG app and must be charged daily (battery life 18 hours). Our patients are provided with an iPhone for study use and are trained in using the AppleWatch.

The AppleWatch is not certified as medical device, but the ECG data collected by the AppleWatch will be used for research purposes only and not for therapeutical or diagnostical purposes.

The second wearable will be the PulseOn device. The battery lasts over two weeks. No additional device is needed for writing an ECG. AF screening is also performed photoplethysmographically. In the case of detection of an arrhythmic pulse curve, this is communicated by vibration. By laying the other hand on the device, a 1-channel ECG is performed for registration. Regular data transfer is done at the patient's home via a gateway device to the PulseOn server. The Core lab will monitor the data transmission. Although PulseOn is a certified medical device, the ECG data collected by the PulseOn device will be used for research purposes only and not for therapeutical or diagnostical purposes. The ICM is the gold standard for recording relevant arrhythmias.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Prevention
盲法
None

入排标准

年龄范围
60 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Study participation in Find-AF 2
  • Randomization in the intervention arm of the Find-AF 2 study and presence of an implanted event recorder (Medtronic Reveal LINQTM Insertable Cardiac Monitor)
  • Signed informed consent
  • All inclusion criteria of the Find-AF 2 study are met (according to protocol version Final 4.0, dated 08.05.2024):
  • i. Recent symptomatic ischemic stroke within the last 30 days (sudden focal neurologic deficit lasting > 24 h consistent with the territory of a cerebral artery) If the neurologic deficit lasted < 24 h a corresponding lesion* on brain imaging is needed.
  • ii. Age ≥ 60 years. iii. Patient without or with only slight disability (modified Rankin Scale score ≤ 2) before onset of stroke-related symtoms.
  • iv. Written informed consent
  • * Corresponding lesion can be an acute lesion on diffusion-weighted magnetic resonance imaging, native computed tomography (CT) or CT perfusion imaging or a recent occlusion or intracranial thrombus on angiography (CTA, MRA, DSA)

排除标准

  • Expiration of the battery of the event recorder in <3 months
  • No in ICM data transmission possible (e. g. missing compliance)
  • Poor ECG data quality according to core lab evaluation (e.g. permanent oversensing), which prevents meaningful evaluation of the event recorder data
  • Exclusion criteria of the Find-AF 2 study (according to protocol version Final 4.0, dated 08.05.2024):
  • i. Known history of atrial fibrillation/flutter or atrial fibrillation/flutter on admission ECG.
  • ii. Current indication or contraindication for oral anticoagulation at randomisation.
  • iii. Intracerebral bleeding in medical history iv. Patient scheduled for ECG-monitoring lasting > 7 days (Holter-ECG, implanted loop recorder, etc.).
  • v. Implanted pacemaker device or cardioverter/defibrillator or implanted cardiac monitor.
  • vi. Patient not willing to be treated with oral anticoagulants vii. Carotid artery stenosis ipsilateral to the current ischemic stroke needing operation or intervention.
  • viii. History of carotid endarterectomy or percutaneous stent intervention of cerebral or cervical artery within the last 30 days.
  • ix. Life expectancy <1 year for reasons other than stroke (e.g. metastatic cancer).
  • x. Patients under legal supervision or guardianship xi. Psychological/mental or other inabilities to supply required information (e.g. fill out the questionnaire due to dementia, language difficulties, ... ) or participate in the required tests xii. Participation in other randomized interventional trials xiii. Suspected lack of compliance

研究组 & 干预措施

AppleWatch

Experimental

semi-continuous heart rhythm monitoring with AppleWatch

for 12 weeks

干预措施: Wearable (Device)

PulseOn

Experimental

semi-continuous heart rhythm monitoring with PulseOn device

for 12 weeks

干预措施: Wearable (Device)

结局指标

主要结局

sensitivity as a function of AF duration

时间窗: from the date of device handover to the date of device return

the probability that an AF episode will be detected as it depends on the duration of the episode

次要结局

  • Time worn(from the date of device handover to the date of device return)
  • Detection sensitivity as a function of AF duration(from the date of device handover to the date of device return)
  • ECG compliance(from the date of device handover to the date of device return)
  • Overall sensitivity(from the date of device handover to the date of device return)
  • Time to first ECG-confirmed AF episode(from the date of device handover to the date of device return)
  • Overall specificity(from the date of device handover to the date of device return)
  • False discovery rate (1-PPV (positive predictive value)(from the date of device handover to the date of device return)
  • For the ICM: What proportion of detected signals are available as ECGs?(from the date of device handover to the date of device return)
  • For the ICM: What is the false discovery rate of the available ECGs?(from the date of device handover to the date of device return)
  • Do patients with an ICM claim to be willing to be randomized to an ICM vs a wearable?(after 12 weeks)
  • Patient satisfaction with the wearable(after 12 weeks)

研究者

发起方
University of Leipzig
申办方类型
Other
责任方
Principal Investigator
主要研究者

Rolf Wachter

Prof. Dr.

University of Leipzig

研究点 (26)

Loading locations...

相似试验