Utilization of Airway Stabilizing Rod to Assist With Laryngeal Mask Airway Guided Fiberoptic Intubation in Adults With Obesity
试验速览
- 阶段
- 不适用
- 状态
- Enrolling By Invitation
- 入组人数
- 20
- 试验地点
- 1
- 主要终点
- Time to Intubation
研究概览
简要总结
The FASTER stabilizing rod offers the distinct advantage of intubating through the laryngeal mask airway with a fiberoptic scope via the FASTER stabilizing rod. The device allows for the provider to insert the endotracheal tube (ETT) with visual confirmation using the fiberoptic scope into the trachea. The device then allows for the laryngeal mask airway to be removed while stabilizing the ETT to ensure the ETT does not get dislodged.
The purpose of this protocol is to clinically test the validated prototype that the investigators have built and previously tested in adults with obesity.
The primary aims are to evaluate 1) the time to intubation and 2) the number of intubation attempts. The secondary aim is to note any complications from time to intubation to PACU discharge.
These complications include: Hypoxemia (10% decrease from baseline for 45 seconds)1 Airway trauma (minor) Esophageal intubation Laryngospasm Bronchospasm Oro-pharyngeal bleeding Arrythmia Emesis Epistaxis Dental damage Post-operative sore throat Post-operative hoarseness Accidental extubation during removal of the LMA.
详细描述
When a patient cannot be ventilated and/or intubated, the guidelines for airway management (ASA difficult airway algorithm) dictate that a laryngeal mask airway (LMA) be used as a rescue device to oxygenate and ventilate the patient. However, an LMA is generally temporary and ultimately needs to be replaced by an endotracheal tube (ETT).
At present, providers can use an exchange catheter through the LMA to place the ETT. However, all current techniques to place the ETT through the LMA are done WITHOUT direct visualization or the ability to provide oxygenation or ventilation. This has the possibility of either accidental tracheal extubation or esophageal intubation as well as the possibility of causing trauma to the airway, particularly of concern in a patient with a difficulty airway.
To bridge this gap, the investigators developed an innovative device called the FASTER that would allow for patients (children through adults) to have an ETT placed through the LMA under direct vision and while being able to oxygenate and ventilate, greatly improving safety.
The first step was to create a prototype that was validated in a mannequin (H-47253 ). Following this validation, the investigators created and successfully performed a feasibility study in children without difficult airway at Texas Children's demonstrating success and no adverse events (H-47253) . Following this feasibility study, and despite the FASTER device being completely external to the patient, given that the study was performed in children, the investigators obtained an IDE from the FDA for study in children specifically with difficulty airways. At present, the investigators have successfully completed an initial study in children (n=20) (H-50120) all with difficulty airways without any adverse events. In this study, children that were previously difficult to intubate having an average of three intubating attempts were intubated in a single attempt in an average of just 66 seconds.
The objective for this protocol is to demonstrate feasibility in using this device in adult obese patients. In this study, the investigators will be using this device that is completely external to the patient and only in adults (not including any protected classes of patients).
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Device Feasibility
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Adult (18-64 yrs),
- •Geriatric (65+ yrs)
- •BMI > 35 kg/m2
- •elective surgery requiring intubation
排除标准
- •pregnant woman
- •incarcerated patient
- •patient refusal
研究组 & 干预措施
Morbid Obesity
Elective surgery requiring intubation, Age > 18, BMI > 35 kg/m2
干预措施: Fiberoptic Assisted Endotracheal Rod Intubation (Device)
结局指标
主要结局
Time to Intubation
时间窗: 3 minutes
Time of disconnecting the circuit from supraglottic airway (SGA) to the presence of end tidal carbon dioxide (ETCO2) for intubation.
Number of Intubation Attempts
时间窗: 5 minutes
Defined as failure to capture end tidal carbon dioxide after completion of intubation.
次要结局
- Complications(Up to 1 day)
研究者
Kevin W Duong
Assistant Professor
Baylor College of Medicine