跳至主要内容
临床试验/NCT02260583
NCT02260583Unknown不适用

EFFECT OF EXTRACORPOREAL CO2 REMOVAL IN STABLE COPD PATIENTS WITH CHRONIC HYPERCAPNIC RESPIRATORY FAILURE:A PILOT STUDY

IRCCS Azienda Ospedaliero-Universitaria di Bologna2 个研究点 分布在 1 个国家目标入组 15 人开始时间: 2014年10月最近更新:
适应症
干预措施

试验速览

阶段
不适用
入组人数
15
试验地点
2
主要终点
arterial blood gases

研究概览

简要总结

Chronic hypercapnic respiratory failure is common in stable COPD patients in a terminal phase of their disease In an attempt to correct or slow down the rate of rise of PaCO2, long-term noninvasive mechanical ventilation (NIV) has been proposed.

Only very few studies demonstrated the clinical efficacy of NIV. Indeed this technique is not always well tolerated and therefore it may be effective only in a subset of patients The aim of this study is to assess the feasibility and safety of "one shot" extrcorporeal CO2 removal device, in reducing the PaCO2 level

详细描述

Chronic hypercapnic respiratory failure is common in stable COPD patients in a terminal phase of their disease In an attempt to correct or slow down the rate of rise of PaCO2, long-term noninvasive mechanical ventilation (NIV) has been proposed.

Only very few studies demonstrated the clinical efficacy of NIV. Indeed this technique is not always well tolerated and therefore it may be effective only in a subset of patients Recently extracorporeal CO2 removal have been shown to avoid the need of endotracheal intubation in COPD patients with an episode of Acute Hypercapnic Respiratory Failure In this pilot physiological study we want to assess the safety and efficacy of this technique in reducing the PaCO2 level in those COPD patients with chronic hypercapnic respiratory failure non responding to chronic NIV.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 90 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • COPD ( FEV1/CVF <0.70 post bronchodilation)
  • stable PaCO2 >55 mmHg non respondent to long-term NIV (at least one week). This means a decrease in PaCO2 during spontaneous breathing, at least 4 hrs after the termination of NIV, of< 6%
  • pH > 7.35
  • clinical stability

排除标准

  • Mean Arterial Pressure < 60 mmHg
  • contra-indication to heparin
  • Body Mass Index (BMI) > 30 kg/m2;
  • presence of sleep apnea or overall syndrome

研究组 & 干预措施

extracorporeal CO2 removal device

Experimental

the patients will be enroll to start a "one shot" session of extracorporeal CO2 removal. The patient will be connected to the device via a double lumen catheter inserted in the femoral vein An ECCO2R device based on a modified continuous venovenous hemofiltration system will be used. Blood flow is driven by a roller nonocclusive pump (0-450 mL/min) through a polypropylene oxygenator ; priming volume, 100 mL; contact surface area, 1.35 m2; maximum blood flow rate, 7 L/min) that is connected to a fresh gas flow source delivering 100% oxygen at a constant rate of 8 L/min. Exiting the oxygenator, blood is driven to a hemofilter.

干预措施: extracorporeal CO2 device (Device)

结局指标

主要结局

arterial blood gases

时间窗: 30 days

次要结局

  • respiratory rate, dyspnea(30 days)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

dr. Stefano Nava

PRofessor of Respiratory Medicine

IRCCS Azienda Ospedaliero-Universitaria di Bologna

研究点 (2)

Loading locations...

相似试验

Effect of Extracorporeal CO2 Removal in Stable... | 临床试验