临床试验/NCT02666144
NCT02666144已完成不适用

Comparison of Optic Nerve Head and Retinal Nerve Fiber Layer Parameters Derived From Two Different Methods of Scan Alignment

Heidelberg Engineering GmbH0 个研究点目标入组 48 人开始时间: 2016年2月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
48
主要终点
Agreement (Differences) of peripapillary retinal nerve fiber layer thickness

研究概览

简要总结

This prospective, monocentric, non-invasive clinical study is designed to measure normal structural parameters of the optic nerve head, the peripapillary retinal nerve fiber layer, and the macula using the Heidelberg Spectralis OCT device. This study is conducted in normal, healthy volunteers and glaucoma patients. The main goal of the study is to provide an analysis of the comparability of these parameters between two different software versions and their respective method of scan centration on the optic disc center. The study will include at least 40 eyes of 40 subjects; 20 normal, healthy subjects and 20 glaucoma patients. All subjects will undergo Spectralis OCT imaging, biometric and ophthalmoscopic examination, and visual field testing in one single visit. Total study duration (first patient first visit to last patient last visit) is anticipated to be approximately 4 weeks.

研究设计

研究类型
Observational
观察模型
Case Control
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Able and willing to undergo the test procedures, give consent, and to follow instructions
  • Subjects that understand the nature of the trial
  • Signed informed consent
  • Age : 18 years or older
  • For "normal subjects", "normal" means, there is no reason that would prevent imaging of the eye, therefore:
  • Self-reported healthy eyes without prior intraocular surgery (except cataract surgery and laser in situ keratomileusis) and without clinically significant vitreal, retinal or choroidal diseases, diabetic retinopathy, or disease of the optic nerve (e.g. impacting central VA or RNFLT measurements as determined by the expertise of the investigator)
  • Visual field GHT within normal limits
  • For "glaucoma subjects": Early to advanced glaucoma according to existing medical charts and visual field GHT outside normal limits on at least two occasions during the testing.
  • Refraction between +6 and -6 diopters spherical equivalent and astigmatism ≤ 2 diopters
  • When both eyes are eligible, one randomly selected eye will be evaluated in the analysis

排除标准

  • Vulnerable subjects (as defined in ISO 14155 GCP)with the exception of employees of the site, and , if applicable, students of the respective university. Staff that is directly involved in the study is excluded from participation.
  • subjects unable to read or write
  • Unreliable visual field. The reliability indices should be used as guide as well as the perimetrist's notes.
  • Unusable disc stereo photos.
  • Inability to undergo the tests.
  • Insufficient quality of Spectralis OCT images (this is not determined until after Spectralis OCT examination, and is an unusual circumstance).
  • Minimum requirements are:
  • Retina completely included in image frame,
  • Quality Score ≥ 20 in the stored ART mean images, and
  • For ONH-R scan: Center position error ≤ 100 μm.
  • Note: Inability of a subject to perform one of the two scan patterns or insufficient image quality in one scan pattern does not exclude the subject or eye from the study.

结局指标

主要结局

Agreement (Differences) of peripapillary retinal nerve fiber layer thickness

时间窗: 4 weeks

Agreement (Differences) of peripapillary retinal nerve fiber layer thickness in sectors temporal, nasal, nasal superior, nasal inferior, temporal superior and temporal inferior when measured with two different software versions.

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor