临床试验/NCT01060306
NCT01060306撤回不适用

Prospective Optical cohereNce Tomography Evaluation of neoINtimal Coverage of a biodegrAdable Polymer-based Drug-eluting Stent

Ospedale Santa Maria Goretti1 个研究点 分布在 1 个国家开始时间: 2010年1月最近更新:
适应症

试验速览

阶段
不适用
状态
撤回
发起方
试验地点
1
主要终点
Assessment of neointimal coverage of the biodegradable polymer-based Biolimus A9-eluting stent (Biomatrix stent) after full drug elution and polymer biodegradation

研究概览

简要总结

PONTINA aims at assessing by optical coherence tomography the neointimal coverage of the biodegradable polymer-based Biolimus A9-eluting stent (Biomatrix stent) after full drug elution and polymer biodegradation (6 months), at one month after this time-point (7 months) and, as a comparator, of its bare metal stent counterpart (Gazelle stent) at 1 month after implantation.

研究设计

研究类型
Observational
观察模型
Case Control
时间视角
Prospective

入排标准

年龄范围
50 Years 至 85 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • age >50 years
  • de novo lesion
  • lesion length <24 mm
  • reference vessel diameter 3 mm

排除标准

  • low compliance to dual antiplatelet therapy
  • life expectancy <1 year
  • allergy to any drug or substance use prior, during or after percutaneous coronary intervention
  • chronic renal insufficiency
  • low left ventricle ejection fraction (<35%)
  • recent acute myocardial infarction
  • previous coronary intervention
  • off-label indication to stenting
  • participation in another investigation
  • refusal to participate to the study

结局指标

主要结局

Assessment of neointimal coverage of the biodegradable polymer-based Biolimus A9-eluting stent (Biomatrix stent) after full drug elution and polymer biodegradation

时间窗: 6 months

次要结局

  • Assessment of neointimal coverage of the biodegradable polymer-based Biolimus A9-eluting stent (Biomatrix stent) one month after full drug elution and polymer biodegradation(7 months)
  • Comparison of neointimal coverage of the biodegradable polymer-based Biolimus A9-eluting stent (Biomatrix stent) one month after full drug elution and polymer biodegradation and of its bare metal stent counterpart (Gazelle) one month after implantation(7 months)
  • Comparison of the neointimal coverage of the biodegradable polymer-based Biolimus A9-eluting stent (Biomatrix stent) after full drug elution and polymer biodegradation (6 months) and at one month after this time-point (7 months)(7 months)

研究者

发起方
Ospedale Santa Maria Goretti
申办方类型
Other
责任方
Principal Investigator
主要研究者

Gregory Sgueglia, MD

MD, PhD

Ospedale Santa Maria Goretti

研究点 (1)

Loading locations...

相似试验