Utility and Usability of ActivSight™ Laser Speckle Imaging in Visualization of Tissue Perfusion and Blood Flow During Esophageal Surgery in Humans
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 入组人数
- 70
- 试验地点
- 4
- 主要终点
- Episodes of intraoperative decision change based on display
研究概览
简要总结
ActivSight™ combines an innovative form factor and proprietary software to deliver precise, objective, real-time visualization of blood flow and tissue perfusion intraoperatively for laparoscope-based surgery. A small adaptor that fits between any existing laparoscope and camera systems and a separate light source placed along any current commercial system will deliver objective real-time tissue perfusion and blood flow information intraoperatively.
Primary Objective: To determine the feasibility of ActivSight™ in detecting and displaying tissue perfusion and blood flow in the conduit and foregut anastomoses in esophageal resection/reconstructive surgery. The investigators will compare the precision and accuracy among the naked eye inspection, ICG and LSCI in assessing the vascularity of the conduit.
详细描述
Design:
- This is a prospective interventional cross-over study where ActivSight™ will be used in sequence to the standard practice of visualizing perfusion status of the conduit using the naked eye visual inspection and ICG during esophageal resection.
- Feasibility will be determined by technically successful completion of intended visualization.
- Safety will be determined through clinical assessments and evaluation of any adverse event.
- Assessment of preliminary efficacy will be performed through analysis of any intraoperative decisions made based on visual display as compared to standard endoscopic approach, or non-inferiority to ICG-based visualization and usability.
- Patient outcome and follow up to Postoperative day 28 will be monitored for clinical outcome.
- Target enrollment for the assessment of esophageal anastomoses is a total of seventy patients powered to detect ~ 2-3 cm discordance between ICG and LSCI lines of demarcation between well vascularized and less vascularized sites in the gastric conduit. Since ActivSight™ can detect the difference of > 2 cm between perfused versus less perfused in comparison to ICG with 80 % confidence at p<0.05 in a sample size of n = 21, the investigators estimate that the study will require an accrual of 63 patients. With potential unforeseen dropout and mortality, the investigators will recruit a total of 70 patients for the proposed study.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- 未提供
排除标准
- 未提供
研究组 & 干预措施
ActivSight Group
Patients undergoing esophagectomy with ActivSight (n=70)
干预措施: ActivSight (Device)
结局指标
主要结局
Episodes of intraoperative decision change based on display
时间窗: 1 day
Yes/No if surgeons changed intraoperative planning/decisions based on ActivSight™, with additional details (what did they change and why) requested if yes.
Resolution and objectivity of display of ActivSight™.
时间窗: 1 day
Rate on a scale of 1-5 (1 = Difficult to use or Unsatisfied - 5 = no training required or very satisfied): How was the display quality of ActivSight on the intended field and target tissue of interest?
Usability of ActivSightTM by surgeon, as quantified by Likert scale.
时间窗: 1 day
Likert scale ratings will serve as an outcome for feasibility. Scale 1-5 question (1=strongly disagree, 2=slightly disagree, 3=neutral, 4=slightly agree, 5=strongly agree): "ActivSightTM was easy to use while operating."
Usability of the device by surgeon and support personnel satisfaction;
时间窗: 1 day
Likert scale ratings will serve as an outcome for feasibility. Scale 1-5 question (1=strongly disagree, 2=slightly disagree, 3=neutral, 4=slightly agree, 5=strongly agree):
Incidence of Adverse Events in 28 days following use of ActivSight™
时间窗: 28 days
To determine safety of ActivSight™ in patients undergoing esophageal surgery, as defined through clinical assessments and evaluation of use related adverse events intraoperatively and a routine follow up at 28 days following surgery. ActivSight™ will be deemed safe if no hardware (adaptor or light source)-related major (serious) adverse event is encountered in the treated patients and if less than 2 hardware-related minor adverse events are encountered. Adverse events will be summarized descriptively and tabulations on the type, severity, and relationship to application will be performed and any changes of outcomes from baseline on follow up will be examined using the nonparametric Wilcoxon rank test.
Preparation time of ActivSight™.
时间窗: 1 day
Rate on a scale of 1-5 (1 = Difficult to use or Unsatisfied - 5 = no training required or very satisfied): How easy was ActivSight to set up?
Latency of display of ActivSight™.
时间窗: 1 day
Rate on a scale of 1-5 (1 = Difficult to use or Unsatisfied - 5 = no training required or very satisfied): How specifically did ActivSight display the intended field and the target tissue of interest?
Specificity of display of ActivSight™.
时间窗: 1 day
Specificity of display will serve as an outcome for feasibility. Yes/No question for surgeon: "Does the perfusion information displayed by ActivSightTM reflect the expected pattern of blood flow interruption?"
Support personnel satisfaction with ActivSightTM, as quantified by Likert scale.
时间窗: 1 day
Likert scale ratings will serve as an outcome for feasibility. Scale 1-5 question (1=strongly disagree, 2=slightly disagree, 3=neutral, 4=slightly agree, 5=strongly agree): "ActivSightTM was easy to set up for the procedure."
User feedback on utility of relative perfusion unit display versus color heatmap
时间窗: 1 day
Likert scale ratings will serve as an outcome for feasibility. Scale 1-5 question (1=strongly disagree, 2=slightly disagree, 3=neutral, 4=slightly agree, 5=strongly agree):
次要结局
- Ability of ActivSightTM to display perfusion.(1 day)
- Ability of ActivSightTM to display blood vessels.(1 day)