Evaluation of the Performance of the VenusP-ValveTM System in Patients with Native RVOT Dysfunction

Venus MedTech (HangZhou) Inc.1 个研究点 分布在 1 个国家目标入组 60 人开始时间: 2024年6月11日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
招募中
入组人数
60
试验地点
1
主要终点
The rate of procedure or device related mortality at the 30 days follow-up visit post procedure

研究概览

简要总结

A prospective, multi-center, non-randomized interventional study to evaluate the safety and effectiveness of the VenusP-ValveTM System in patients with native right ventricular outflow tract (RVOT) dysfunction.

Post procedure, a clinical visit will be scheduled at pre-discharge, 30 days, 6 months, 12 months, and annually thereafter to 10 years.

About 60 subjects will be enrolled in this study. Data analysis will be performed after all enrolled subjects complete 6-month follow-up and the primary endpoint analysis report will be submitted to FDA for PMA approval.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
12 Years 至 —(Child, Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Weight ≥25kg (55 lbs.)
  • •Age ≥ 12 years olds
  • •Patients have a dysfunctional native RVOT with severe pulmonary regurgitation (i.e., severe pulmonary regurgitation as determined by echocardiography or pulmonary regurgitant fraction ≥30% as determined by cardiac magnetic resonance imaging) and without significant pulmonary stenosis (significant pulmonary stenosis is defined as gradient more than 25mmHg) and are clinically indicated for intervention:
  • •1) For symptomatic patients, fitting the following criteria:
  • •Severe pulmonary regurgitation measured by echocardiogram or pulmonary regurgitant fraction ≥30% measured by CMR 2) For asymptomatic patients, including any 2 of the following criteria:
  • •Mild or moderate RV or LV systolic dysfunction.
  • •Severe RV dilation (RVEDVI ≥145 mL/m2 or RVESVI ≥ 75 mL/m2or RVEDV >2 × LVEDV).
  • •Progressive reduction in objective exercise tolerance.
  • •Patient is willing to consent to participate in the study and will commit to completion of all follow-up requirements.

排除标准

  • •Clinical or biological signs of infection including active endocarditis.
  • •Echocardiographic evidence of intracardiac mass, thrombus, or vegetation.
  • •Leukopenia, anemia, thrombocytopenia, or any known blood clotting disorder, deemed clinically significant after consultation with Haemato-oncology specialists.
  • •Inappropriate anatomy for femoral or right internal jugular vein (RIJ) introduction and delivery of the VenusP-ValveTM System.
  • •RVOT anatomy or morphology that is unfavorable for device anchoring.
  • •Anatomy unable to accommodate VenusP-Valve delivery system.
  • •Angiographic evidence of coronary artery compression that would result from transcatheter pulmonary valve replacement (TPVR).
  • •Emergency interventional/surgical procedures within 30 days prior to the index procedure.
  • •Planned significant and relevant concomitant procedure at time of VenusP-Valve implant.
  • •Any planned interventional/surgical procedures to be performed within the 30 days follow-up from VenusP-Valve implant.
  • •Known history of intravenous drug abuse in the past 5 years, without certificate of completion of rehabilitation from a specialist.
  • •Major or progressive non-cardiac disease resulting in a life expectancy of less than one year.
  • •Known hypersensitivity or contraindication to antiplatelet, antithrombotic medications, or nitinol (titanium or nickel) leading to be unable to undergo index procedure per physicians' judgement
  • •Positive pregnancy test at baseline (prior to CT angiography and again prior to implant procedure) in female patients of child-bearing potential.
  • •Currently participating in an investigational drug or another device study.
  • •Patient or guardian unwilling or unable to provide written informed consent or comply with follow-up requirements.
  • •The investigators consider that the patients are not suitable to participate in this research.

研究组 & 干预措施

TPVI

Experimental

干预措施: VenusP-ValveTM System (Device)

TPVI

Experimental

干预措施: Transcatheter pulmonary valve implantation (TPVI) (Device)

结局指标

主要结局

The rate of procedure or device related mortality at the 30 days follow-up visit post procedure

时间窗: At 30 Days Post Procedure

Freedom from procedure or device related mortality at 30 days

The rate of re-intervention and acceptable hemodynamic function at 6 Month follow-up visit post procedure

时间窗: At 6 Months Post Procedure

Freedom from VenusP-Valve re-intervention and acceptable hemodynamic function at 6 months defined as: 1. No more than mild regurgitation measured by CMR; AND 2. Mean RVOT gradient as measured by echocardiography ≤35mmHg.

次要结局

  • The rate of technical Success during the procedure(During the Procedure)
  • The rate of all-cause mortality, procedure or device related mortality, and procedure or device related Major Adverse Cardiac and Cerebrovascular Events (MACCE) out to 10 years(Through Ten Years Post Procedure)
  • The rate of acceptable hemodynamic performance at 30 days, 1-5 years, 7 years and 10 years.(At 30 Days, 1-5 Years, 7 Years and 10 Years Post Procedure)
  • The rate of procedure success out to 30 days(At 30 Days Post Procedure)
  • Characterization of quality-of-life scores out to 5 year, and at 10 years(Through Five Years Post Procedure, and at 10 Years Post Procedure)
  • New York Heart Association (NYHA) classification Through out to 10 years(Through Ten Years Post Procedure)
  • The rate of valve dysfunction out to 10 years(Through Ten Years Post Procedure)