跳至主要内容
临床试验/NCT02551354
NCT02551354已完成不适用

Estimation of Pain During Epidural Analgesia During Labor - a Monocentric Study

Centre Hospitalier Universitaire de Saint Etienne1 个研究点 分布在 1 个国家目标入组 40 人开始时间: 2012年11月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
40
试验地点
1
主要终点
Pupil diameter variability

研究概览

简要总结

Epidural regional anesthesia is a technique to eliminate or lessen pain during obstetric labor and childbirth. It consists in establishing a catheter into the epidural space and to block the transmission of pain sensations by injecting a local anesthetic and an opioid. In 10-25% of cases the epidural does not give perfect results, causing it to test its effectiveness, which is mainly done by questioning the patient on mitigation or disappearance of pain. This collaboration of patients is sometimes limited in our care structure by the inability to assess or express the pain, mainly due to cultural differences or language barriers, which can represent up to 15% of women in our institution. This led to develop objective measures of pain techniques used at the bedside.

Pupil diameter (PD) varies under the double influence of sympathetic system (Σ), dilator of the pupil, and parasympathetic system (pΣ).

The PD increases in response to painful stimulation, in proportion to the intensity of the nociceptive stimulus. This variation of PD has been proposed as a means of evaluation of pain in patients under general anesthesia, but has been little studied in conscious subjects.

There are other permanent changes in the PD, due to constant interaction between Σ and pΣ systems. Few data have been published to date on this PD variability (PDV).

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Prevention
盲法
None

入排标准

年龄范围
18 Years 至 45 Years(Adult)
性别
Female
接受健康志愿者
否

入选标准

  • •Obstetrical Labor
  • •Able to rate their pain using VAS
  • •dilatation of the cervix under 6 centimeters
  • •Written consent

排除标准

  • •- Not having a anesthesia consultation during the 48 hours before delivery
  • •With a contra-indication for an epidural
  • •To which an incident occurred during a previous epidural using a medication used in the study
  • •Operated a unilateral or bilateral ocular surgery modifying the possibilities of variation of pupil diameter
  • •general anesthesia in the seven days preceding delivery
  • •Carry a pacemaker or heart grafted
  • •Having Parkinson's disease history, insulin or non-insulin diabetes or chronic alcoholism
  • •Having cardiac arrhythmia (atrial fibrillation or frequent extrasystoles)
  • •Treated for hypertension by receptor antagonists of angiotensin type 2
  • •anti-arrhythmic treatment or blocker,
  • •Refusing to participate in the study
  • •With a contra-indication for the use of ropivacaine and sufentanil.

研究组 & 干预措施

Patients

Experimental

Pain assess by :

  • Visual Analogic Scale (VAS).
  • Portable video pupillometer

干预措施: Portable video pupillometer (Device)

结局指标

主要结局

Pupil diameter variability

时间窗: From baseline to fifteen minutes after start of Epidural regional anesthesia

Compare Pupil Diameter Variability (PDV) measured before Epidural regional anesthesia and after Epidural regional anesthesia. PDV is aera under the curve of Pupil Diameter from start of the contraction (baseline) to time to peak of the contraction.

次要结局

  • pupil diameter(From baseline to fifteen minutes after start of Epidural regional anesthesia)
  • Visual Analogic Scale (VAS)(From baseline to fifteen minutes after start of Epidural regional anesthesia)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验