跳至主要内容
临床试验/NCT04501185
NCT04501185招募中不适用

Comparison of Clinical Results of Two Cementless Femoral Stem

Chang Gung Memorial Hospital1 个研究点 分布在 1 个国家目标入组 60 人开始时间: 2020年6月1日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
发起方
入组人数
60
试验地点
1
主要终点
Numerical Rating Scale

研究概览

简要总结

In the present study, two types of cementless femoral stem- UTS Stem and UTF-reduced Stem- were utilized in total hip arthroplasty. Due to the design for proximal femur fixation, both femoral stems could prevent stress shielding around the implant, further preventing osteolysis. The difference between both femoral stems is the length, in which UTS Stem is 20% shorter than UTF-reduced Stem. The clinical outcomes of both femoral stems will be compared. Both femoral stems are expected to have equally good radiologic outcome and clinical performance.

详细描述

Total hip arthroplasty (THA) is a common orthopedic procedure aimed at improving joint function and alleviating pain in patients with hip joint degeneration. However, the phenomenon of stress shielding-whereby the mechanical properties of the prosthesis lead to reduced load transmission to the surrounding bone-can compromise long-term outcomes. In particular, uncemented THA designs are susceptible to stress shielding, potentially resulting in bone resorption and implant loosening.

To address this challenge, the study focuses on optimizing femoral stem fixation within the proximal femur in two specific stem designs: the UTS and the UTF reduced stem. These stems are strategically designed to enhance load transfer while minimizing stress shielding effects.

A total of 60 patients who are undergoing total hip arthroplasty at Linkou Chang Gung Memorial Hospital will be recruited, including 30 patients in the "UTS" group and 30 patients in the "UTF-reduced" group.The clinical assessments including Success Rate of prosthesis, Numerical Rating Scale (NRS) for pain, Harris Hip Score (HHS), Medical Outcome Study Short Form-36 (SF-36) and : Dual-energy X-ray absorptiometry (DEXA) scanning for bone mineral density monitoring.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
20 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients who receive total hip arthroplasty with either a UTS femoral stem or a UTF-reduced femoral stem after June, 2020
  • Patients who have not received total hip arthroplasty in the past

排除标准

  • Patients who are unable or unwilling to return for follow-up
  • Patients who suffer from mental disorders

结局指标

主要结局

Numerical Rating Scale

时间窗: Change from baseline at 1 year

Numerical Rating Scale is a patient-reported outcome measure. The scale ranges from 0 to 10. A score of 0 represents no pain, while a score of 10 represents extreme pain.

Harris Hip Score

时间窗: Change from baseline at 1 year

Harris Hip Score includes 4 sections that evaluate pain, function, deformity, and range of motion. Total scores is from 0 to 100, higher scores represent a better outcome.

DEXA scanning

时间窗: Change from baseline at 1 year

DEXA scanning is used to monitor and quantify bone mineral density, which helps to understand if the implant has an effect on the change of bone mineral density.

Success rate

时间窗: Duration of 1 year

Failure is defined as removal or revision of any components as a result of mechanical failure or complications. Sucess is defined as implants that are sucessfully implanted without any failure for the duration of 1 year. The success rate will be represented as a percentage (%).

Medical Outcome Study Short Form-36

时间窗: Change from baseline at 1 year

SF-36 is a set of generic, coherent, and easily administered quality-of-life measures. These measures rely upon patient self-reporting and are now widely utilized by managed care organizations and by Medicare for routine monitoring and assessment of care outcomes in adult patients. It consists of two sections, physical component summary and mental component summary, with 36 items in total.

次要结局

  • Radiolucent line(Change from baseline at 1 year)
  • Morphology of the proximal femur(at baseline)
  • Valgus/Varus alignment(Change from baseline at 1 year)

研究者

发起方
Chang Gung Memorial Hospital
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验