跳至主要内容
临床试验/NCT03409575
NCT03409575已完成不适用

Efficacy of Two Different Method of Neuromuscular Electrical Stimulation on Quadriceps Strength, Fatigue and Physical Function in Geriatric Population

Sevim ACARÖZ CANDAN2 个研究点 分布在 1 个国家目标入组 44 人开始时间: 2018年2月5日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
44
试验地点
2
主要终点
Timed up and go test

研究概览

简要总结

The decline in physical function and strength was seen by the nature of aging. The older adults often complain of fatigue. For these reasons, proper rehabilitation approaches should be used to ensure healthy life and to keep the quality of life at the highest possible level by minimizing the decline seen with aging process. Exercise programs and Neuromuscular Electrical Stimulation (NMES) are applied in rehabilitation to restore muscular strength and improve physical performance. NMES is used to prevent the atrophy of nonuse, to increase joint range of motion, to re-educate muscle, to regulate spasticity, to replace orthosis, to improve motor involvement of muscle fibers. Despite the use of NMES for strengthening in the clinics, the application parameters and methods should be discussed. The frequency, the pulse duration, the on / off time, the amplitude, the waveform of the current and the application time vary between the studies. For geriatric populations, it is recommended that the highest intensity, biphasic symmetrical currents with a frequency in the range of 50-100 Hz, for 100-400 μs, can be pulsed for ideal amplification. NMES is usually practiced by physiotherapists continuously for 20 minutes in to strengthen. However, in recent studies, it has been shown that continuous application of a single-session 100 Hz current for 20 minutes leads to intense fatigue and after a while the effect of the strengthening of the current has been removed. Therefore, intermittent applications have been proposed instead of continuous applications for 20 minutes. Considering the fragility and the presence of sarcopenia in the geriatric population, NMES applications should be preferred in which rest periods are given instead of continuous application for 20 minutes. In the literature, there is no study showing the effect of NMES on Quadriceps strength, fatigue and physical function by using quadriceps stimulation for 20 minutes using different stimulation periods.Therefore, in this study, will be investigated the possible effects of two different methods of NMES on Quadriceps strength, fatigue and physical function.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Supportive Care
盲法
Double (Participant, Outcomes Assessor)

入排标准

年龄范围
65 Years 至 95 Years(Older Adult)
性别
All
接受健康志愿者

入选标准

  • age 60 years or older
  • be able to climb one floor of stairs independently
  • not participate in an exercise program to increase strength or physiotherapy programme.

排除标准

  • having a medical condition in which NMES training is contraindicated
  • having a cognitive impairment
  • having implanted cardiac pacemaker

研究组 & 干预措施

5 minutes stimulation

Other

The biphasic, symmetrical waveform will be used. The 100 Hz current will be applied for 5 minutes.

干预措施: 5 minutes stimulation (Other)

10 minutes stimulation

Other

The biphasic, symmetrical waveform will be used. The 100 Hz current will be applied for 10 minutes.

干预措施: 10 minutes stimulation (Other)

结局指标

主要结局

Timed up and go test

时间窗: 2 minutes

This test will be used to measure the progress of balance, sit to stand, and walking. The participants stands up upon therapist's command walks 3 meters, turns around, walks back to the chair and sits down. The time stops when the patient is seated. Time will be recorded.

6 minute walk test

时间窗: 6 minute

The 6 Minute Walk Test is a sub-maximal exercise test used to assess aerobic capacity and endurance. The distance covered over a time of 6 minutes is used as the outcome by which to compare changes in performance capacity. The participant walk for 6 minutes on 30 meter long way. The total distance will be recorded at the end of the test.

30-Second Chair Stand Test

时间窗: 30 second

The 30CST is a measurement that assesses functional lower extremity strength in older adults. The participant is encouraged to complete as many full stands as possible within 30 seconds. The participant is instructed to fully sit between each stand.The score is the total number of stands within 30 seconds (more than halfway up at the end of 30 seconds counts as a full stand). Incorrectly executed stands are not counted.

次要结局

  • Grip Strength(5 minutes)
  • Berg Balance Scale(10 minutes)
  • Short Physical Performance Battery(3 minutes)
  • Strength of Quadriceps muscle(5 minutes.)
  • Fatigue Severity Scale(5 minutes)

研究者

发起方
Sevim ACARÖZ CANDAN
申办方类型
Other
责任方
Sponsor Investigator
主要研究者

Sevim ACARÖZ CANDAN

Head of Department of Physiotherapy and Rehabilitation

T.C. ORDU ÜNİVERSİTESİ

研究点 (2)

Loading locations...

相似试验