Evaluation of Cataract Lens Hardness Based on Phacoemulsificator Tip Resistance

Ospedale Policlinico San Martino1 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2021年9月1日最近更新:
适应症

试验速览

阶段
不适用
入组人数
20
试验地点
1
主要终点
cataract lens hardness according to LOCS III classification system

研究概览

简要总结

Phacoemulsificaton tip elongation depends upon voltage once resonant frequency of piezoelectric crystals has been reached.

Purpose of the study is to record voltage data of 20 consecutive cataract surgeries in order to evaluate correlation between voltage and LOCS classification of lens nuclei using a system that deploys a feedback mechanism capable of keeping invariant elongation regardless of enountered resistence

详细描述

The R-Evolution (Optikon 2000 Rome, Italy) phaco machine is equipped with a patented system named "minimal stress" that used the direct piezoelectric effect from the resonant ceramics that drive the phacoemulsificator tip to assess in real time and adjust phaco tip elongation that continuously varies according to encountered resistance.

After priming in balanced salt solution, phaco tip elongation and the amount of potential difference (voltage) needed to obtain a ginev elongation in balanced solution is assessed. Once the phaco tip is used during surgery, the resistence offered by the crystalline lens material to the phaco tip reduces actual elongaton which in turn reduces the voltage produced by the directo piezometric effect. The machine uses voltage produced by actual elongation to adjust the diving voltage and therefore can ensure accurate pahco tip elongation under any condition of lens material resistance.

Purpose of the study is to record driving voltage and its variations and evaluate if there is a correlation between phaco tip resistence and drving voltage.

This is evaluated both in vitro activating the phaco tip in increasingly dense glycerol solutions and in real life phaco surgery recording the voltage requested by phaco tip resistence and correlating it to the classification of lens opacity (LOCS III system) clinically used to grade cataract hardness.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 90 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • diagnosis of nuclear or cortical cataract

排除标准

  • previous ocular trauma, previous ocular surgery, connective tissue disease

结局指标

主要结局

cataract lens hardness according to LOCS III classification system

时间窗: at enrolling

lens opacity and estimated nucleous hardness according to international LOCS classification

peak voltage

时间窗: at the time of surgery

maximum voltage necessary to emulsify cataract nucleous

average voltage

时间窗: at the time of surgery

voltage necessary to emulsify cataratct nuclous

次要结局

未报告次要终点