The Impact of Chair Seat Height on the 1-Minute Sit to Stand Test Performance in Chronic Obstructive Pulmonary Disease: a Randomized Cross-over Study
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 55
- 试验地点
- 2
- 主要终点
- Number of repetitions in the 1-min STS test
研究概览
简要总结
The 1-minute sit to stand (1-min STS) test is a standardized test which is used to examine exercise capacity in patients with chronic obstructive pulmonary disease (COPD). The chair seat height used is standardized to 46-48 cm. Using a standard seat height for all patients - irrespective of their body height - may lead to invalid estimates of functional exercise capacity. The objective of this study is to assess whether there is a difference in repetitions during the 1-min STS test if the seat height is adjusted to 90° knee joint angle or the standard height chair of 46 cm is used.
详细描述
In a single-center, randomized crossover study, the investigators aim to elucidate whether there is a difference in repetitions during the 1-min STS test if the seat height is adjusted to 90° knee joint angle or the standard height chair of 46 cm is used.
Patients with COPD referred for pulmonary rehabilitation will be invited to perform one standardised- (chair seat height 46cm) and one individualized (chair seat height adapted to 90° knee flexion) 1-min STS test on two different days in random order.
The tests will be performed after patients are familiarised with the 1-min STS testing procedure and learning effects can be excluded.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Other
- 盲法
- Single (Participant)
入排标准
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients with diagnosed COPD according to a forced expiratory volume in 1s (FEV1) / forced vital capacity (FVC) ratio below the lower limit of normal
排除标准
- •Patients who are not able to bend their knees while sitting on a standard chair (i.e., knee flexion less than 90°)
- •Patients who are not able to understand the instructions of the 1-min STS test, either of language or cognitive reasons
- •Patients who are unable to perform the STS test due to functional disability (i.e., being not able to rise from a chair without hand support), previous surgery, or pain according to the judgement of the responsible physician.
- •Patients who did not sign the informed consent form
结局指标
主要结局
Number of repetitions in the 1-min STS test
时间窗: During pulmonary rehabilitation, approximately 14 days
difference in the amount of sit to stand repetitions in the 1-min STS test from a standard chair (46cm) or an individualized seat height chair of 90° knee joint angle
次要结局
- Sit to stand power index(During pulmonary rehabilitation, approximately 14 days)
研究者
Thomas Riegler
Principal Investigator
Berner Reha Zentrum AG