3D Holographic Guidance, Navigation, and Control (3D GN&C) for Endovascular Aortic Repair (EVAR)

The Cleveland Clinic2 个研究点 分布在 1 个国家目标入组 2 人开始时间: 2023年10月18日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
2
试验地点
2
主要终点
Successful implantation of Cook Zenith AAA Endovascular Graft using the 3D-GN&C device

研究概览

简要总结

This is an Early Feasibility Study to evaluate the usability, safety and functionality of 3D holographic guidance, navigation, and control (3D-GNC) as an adjunct to and confirmed by fluoroscopic imaging to be used with Cook Zenith Flex AAA Endovascular Graft®.

详细描述

The goal of this clinical study is to evaluate the feasibility of using electromagnetic (EM) guidance and tracking to precisely place a Cook Zenith Flex AAA bifurcated stent graft during EVAR. EM guidance and tracking is enabled using a system consisting of the following: 1) experimental 3D guidance, navigation, and control (3D-GNC) software developed by Centerline Biomedical, Inc., integrated with the company's FDA-cleared Intra-Operative Positioning System (IOPS), 2) FDA-cleared compatible sensorized guidewires added to the Cook Zenith Flex delivery system and 3) 3D visualization on the IOPS mobile cart monitor and 3D holographic visualization overlaid on the patient during the procedure using a head mounted display (HMD), the Microsoft HoloLens 2. Planning and execution of each case will be major steps in demonstrating feasibility of the technology beyond non-clinical and preclinical testing.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Other
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • The patient meets the instructions for use (IFU) for the 24-28 mm body Cook Zenith Flex AAA bifurcated stent graft.
  • Adequate iliac/femoral access compatible with the required introduction system
  • Non aneurysmal infrarenal aortic segment (neck) proximal to the aneurysm:
  • i. With a length of at least 15mm ii. With a diameter measured outer wall to outer wall of no greater than 26mm and no less than 20mm iii. With an angle less than 60 degrees relative to the long access of the aneurysm and iv. With an angle less than 45 degrees relative to the axis of the suprarenal aorta c. Iliac artery distal fixation site greater than 10mm in length and 7.5-20mm in diameter (measured outerwall to outerwall).
  • Male/female, aged ≥ 18
  • Patient fulfilling criteria for needing endovascular repair of abdominal aortic aneurysm according to routine clinical practice criteria of the participating center
  • Women of childbearing potential must be non-pregnant, non-lactating, and not planning to become pregnant during the course of the trial; and have a negative urine or serum pregnancy test within 7 days prior to index procedure
  • Provide written informed consent as applicable and defined by site country regulation
  • Stated willingness to comply with all study procedures and availability for the duration of the study

排除标准

  • An individual who meets any of the following criteria will be excluded from participation in this study:
  • Contraindications for Cook Zenith Flex Aortic endograft:
  • Patients with known sensitivities or allergies to stainless steel, polyester, solder (tin, silver), polypropylene, or gold
  • Patients with a systemic infection who may be at increased risk of endovascular graft infection
  • Presence of electronic implants, e.g., cardiac pacemaker, automatic implantable cardioverter/defibrillator (AICD) or nerve stimulator
  • Presence of metallic implants above the knee, e.g., artificial hip
  • Patients not willing or able to give informed consent
  • Pregnant women
  • Patients' inability to have a contrasted CT scan
  • Current or planned participation in any other investigational drug or medical device clinical study that has not completed primary endpoint(s) evaluation;
  • Other medical, social, or psychological issues that in the opinion of the investigator preclude the subjects from receiving this treatment, and the procedures and evaluations pre- and posttreatment
  • Anatomy outside of the IFU for a 24-28 mm Cook Zenith Flex AAA bifurcated stent graft

研究组 & 干预措施

Intervention

Experimental

Electromagnetic guidance and tracking as an adjunct to and confirmed by fluoroscopic imaging to be used with Cook Zenith Flex AAA Endovascular Graft.

干预措施: 3D Holographic Guidance, Navigation, and Control (3D GN&C) (Device)

结局指标

主要结局

Successful implantation of Cook Zenith AAA Endovascular Graft using the 3D-GN&C device

时间窗: During the procedure

Correct positioning of the endovascular stent graft confirmed by fluoroscopic imaging

Number of Participants With Successful Implantation of Cook Zenith AAA Endovascular Graft Using the 3D-GN&C Device

时间窗: By the end of the procedure, average of 2 hours

Number of Patients with Correct positioning of the endovascular stent graft using the 3D-GN\&C device confirmed by fluoroscopic imaging

次要结局

  • Delivery system placement in the intended location(During the procedure)
  • Delivery System Placement in the Intended Location(At the time of the procedure)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验