跳至主要内容
临床试验/NCT07296263
NCT07296263进行中(未招募)不适用

Evaluation of Gadolinium Based Contrast Agents for Portable MR Imaging Systems

Hyperfine6 个研究点 分布在 1 个国家目标入组 85 人开始时间: 2025年12月30日最近更新:
适应症
干预措施
相关药物

试验速览

阶段
不适用
状态
进行中(未招募)
发起方
Hyperfine
入组人数
85
试验地点
6
主要终点
Radiologist-rated lesion border delineation on post-contrast portable MRI

研究概览

简要总结

This is a prospective, multi-center, interventional study designed to evaluate the visualization benefits of FDA approved gadolinium-based contrast agents (GBCAs) in portable magnetic resonance imaging (pMRI) of the brain. The study will enroll adult patients with known or suspected brain lesions involving blood-brain barrier disruption. Each participant will undergo a pre-contrast pMRI scan, receive an intravenous GBCA injection, and then complete a post-contrast pMRI scan using the Swoop® Portable MR Imaging® System. Lesion visualization will be assessed by independent neuroradiologists using standardized scoring criteria. The study will be conducted across a minimum of three sites to ensure diversity in patient population, imaging environments, and GBCA types.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Other
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • To be eligible to participate in this study, an individual must meet all the following criteria:
  • Age ≥18 years Clinical indication of suspected or known brain lesion(s) with focal blood-brain barrier disruption. Preferably, at least one previously documented brain lesion with focal areas of blood-brain barrier disruption categorizable as:
  • intra-axial tumor(s)
  • extra-axial tumor(s)
  • infection/inflammatory lesion(s)
  • Cleared for portable MRI (pMRI) and intravenous GBCA administration per site policy.
  • Adequate peripheral venous access for contrast injection.
  • Able to provide informed consent and comply with brief supine imaging (pre- and post-contrast)

排除标准

  • Participants will be excluded if they meet any of the following criteria:
  • Metallic clips or devices in the brain or eye.
  • Body weight greater than 200 kg.
  • Inability to fit or be positioned appropriately within the Swoop® Portable MR Imaging® System.
  • Inability to remain still or lie flat during the imaging period.
  • Not cleared for GBCA administration due to known hypersensitivity, allergy, or contraindication.
  • Severe renal impairment (eGFR < 30 mL/min/1.73 m²) or acute kidney injury.
  • History of severe reaction to any gadolinium-based contrast agent.
  • GBCA administration within the prior 48 hours (or alternative clearance window defined by institution)
  • Known or suspected pregnancy at the time of imaging.
  • Any medical or behavioral condition that, in the investigator's judgment, would make participation unsafe or interfere with study completion.
  • Subjects may be selectively enrolled or excluded to ensure inclusion of radiology finding subgroups and GBCA agents.

研究组 & 干预措施

Single-Arm: Pre- and Post-Contrast pMRI

Experimental

Participants will undergo portable magnetic resonance imaging (pMRI) using the Swoop® Portable MR Imaging® System (0.064 T), including imaging performed before and after intravenous administration of an FDA-approved gadolinium-based contrast agent (GBCA).

干预措施: Portable MRI (pMRI) (Device)

Single-Arm: Pre- and Post-Contrast pMRI

Experimental

Participants will undergo portable magnetic resonance imaging (pMRI) using the Swoop® Portable MR Imaging® System (0.064 T), including imaging performed before and after intravenous administration of an FDA-approved gadolinium-based contrast agent (GBCA).

干预措施: Gadolinium-Based Contrast Agent (GBCA) (Drug)

结局指标

主要结局

Radiologist-rated lesion border delineation on post-contrast portable MRI

时间窗: 6 months

Blinded neuroradiologists will assess lesion border delineation on post-contrast T1-weighted portable MRI images using a standardized 5-point Likert scale (1 = poor delineation, 5 = excellent delineation). Scores will be summarized using descriptive statistics.

Radiologist-rated lesion internal morphology visibility on post-contrast portable MRI

时间窗: 6 months

Blinded neuroradiologists will evaluate the visibility of lesion internal morphology on post-contrast T1-weighted portable MRI images using a standardized 5-point Likert scale (1 = non-visible, 5 = clearly visible). Scores will be summarized using descriptive statistics.

Radiologist-rated degree of contrast enhancement of target lesions on portable MRI

时间窗: 6 months

Blinded neuroradiologists will rate the degree of lesion contrast enhancement on post-contrast T1-weighted portable MRI images using a standardized 5-point Likert scale (1 = no enhancement, 5 = marked enhancement). Ratings will be summarized descriptively across subjects.

Radiologist-rated lesion border delineation on post-contrast portable MRI

时间窗: 6 months

Blinded neuroradiologists will assess lesion border delineation on post-contrast T1-weighted portable MRI images using a standardized 5-point Likert scale (1 = poor delineation, 5 = excellent delineation). Scores will be summarized using descriptive statistics.

Radiologist-rated lesion internal morphology visibility on post-contrast portable MRI

时间窗: 6 months

Blinded neuroradiologists will evaluate the visibility of lesion internal morphology on post-contrast T1-weighted portable MRI images using a standardized 5-point Likert scale (1 = non-visible, 5 = clearly visible). Scores will be summarized using descriptive statistics.

Radiologist-rated degree of contrast enhancement of target lesions on portable MRI

时间窗: 6 months

Blinded neuroradiologists will rate the degree of lesion contrast enhancement on post-contrast T1-weighted portable MRI images using a standardized 5-point Likert scale (1 = no enhancement, 5 = marked enhancement). Ratings will be summarized descriptively across subjects.

次要结局

未报告次要终点

研究者

发起方
Hyperfine
申办方类型
Industry
责任方
Sponsor

研究点 (6)

Loading locations...