Predictive Factors Determining Continuous Positive Airway Pressure (CPAP) Compliance in Obstructive Sleep Apnea
试验速览
- 阶段
- 不适用
- 发起方
- 入组人数
- 450
- 试验地点
- 1
- 主要终点
- Compliance time to CPAP
研究概览
简要总结
This study aims to determine the average compliance of a patient under CPAP therapy for obstructive sleep apnea as well as the various factors that influence it.
详细描述
Obstructive Sleep Apnea (OSA) is a frequent disease that affects 4% of the male population and 2% of the female population, with well known repercussions on the quality of life (daytime drowsiness, concentration issues, increased motor vehicle accidents, etc) and cardiovascular risk (increased risk of strokes, hypertension, diabetes, CAD, etc.). It is caused by an intermittent relaxation of the throat muscles during sleep, thus blocking the airways and leading to snoring and apnea.
Treatment can involve diets and sports, sleep hygiene techniques, mandibular advancement devices. But the CPAP (continuous positive airway pressure) device remains the first line therapy for OSA. It is very effective at reducing apnea-hypopnea (AHI) and oxygen desaturation indexes (ODI), but poor compliance is often noticed, with only 46% of patients still using the device at 6 months.
Despite numerous studies on the subject, very few have included a large number of patients(>150) or long follow up time (>1 year), or reached conclusive evidence concerning the factors that influence CPAP compliance.
In order to determine these factors, the investigators have taken into account approximately 450 patients over a timeframe of 5 years who have used a CPAP device during the course of their disorder, and established a Kaplan-Meyer estimation of their survival function. The investigators have then used anthropometry (BMI, neck circumference, sex, age, etc.), polysomnography (Epworth score, AHI, ODI, sleep efficiency, etc.) and CPAP (pressures, leaks, etc.) data with a Cox regression in order to determine the factors that influence the compliance of a patient.
The results will allow us to establish the average compliance of a patient under CPAP therapy, as well as the reasons leading to its termination, the factors predicting a decreased compliance and the consequences of stopping the treatment. This will allow us to set up multiple methods of improved follow-up in patients that are predicted recalcitrant to CPAP therapy.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Retrospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •All HDF patients with OSA, treated for at least one day by CPAP, from the period of June 2008 to June 2013.
排除标准
- 未提供
结局指标
主要结局
Compliance time to CPAP
时间窗: 6 years
Survival study taking the noncompliance to CPAP treatment as an event
次要结局
- Predictive factors related to the device for compliance to CPAP (Mask type, use of a humidification, Device type/mode, Pressure set, Cost, Side effects)(6 years)
- Predictive factors related to OSA for compliance to CPAP (Severity score, fatigue and Epworth score, Polysomnography profile (AHI, ODI, Arousal index…), use of alternative treatments)(6 years)
- Predictive factors related to the patient for compliance to CPAP (Sociologic and economic status, medical co morbidities, Anthropometric characteristics)(6 years)
- Predictive factors related to the provider for compliance to CPAP (Attitude of the provider (active, passive), consistency/quality of the follow up)(6 years)
- Cardiovascular outcome/benefits (cardiovascular events; defined by hypertension, coronary event, stroke, diabetes, cardiac insufficiency, arrhythmias)(6 years)
研究者
May Samaha
Moussa Riachy MD FCCP
Saint-Joseph University