简要总结

The purpose of the study is to directly compare two methods of evaluating heart function at the time of your angiogram. In both methods contrast dye is injected into the main heart chamber during the angiogram while x-ray images are taken. One method uses an automatic power injector to deliver the normal volume of contrast; the other method uses hand injection of very low volume of contrast into the main heart chamber. It is hypothesized that hand injection will prove to be an accurate method to estimate ejection fraction (EF) at the time of radial coronary angiography when compared directly to Power LV.

详细描述

Left ventriculography is a routine and accurate method of evaluating left ventricular ejection fraction (EF) at the time of coronary angiography. Power injected left ventriculography (Power LV) using standard volume (36 ml over 3 seconds) of contrast through a 5 Fr. angled pigtail catheter in the left ventricle is currently a routine clinical practice during left heart catheterization via the radial artery. With coronary angiography from the radial approach increasing in popularity there is a growing interest in hand injected left ventriculography (Hand LV) using a very low volume (8ml) of contrast through a 5 Fr. radial angiographic catheter. Potential benefits of this method include reduced contrast load, reduced procedure time and overall reduction in cost (less catheters used per procedure) as the procedure can be completed using a single diagnostic catheter. Potential limitations of this method include reduced opacification of the left ventricle and decreased number of cardiac cycles available to estimate EF. It is currently unknown if Hand LV is accurate in estimating EF when compared to the standard Power LV.

Objective

The primary objective of this study is to directly compare the accuracy of the very low volume Hand LV to the standard volume Power LV in estimating EF.

Methods: This study will be conducted in an outpatient setting. The subjects enrolled in this study will be adults referred for radial coronary angiography with left ventriculography for clinical indications. Subjects will undergo both Hand LV and Power LV at the time of angiography. EF for both Hand LV and Power LV will be estimated for each subject in a blinded fashion by 2 independent experienced cardiologists. Additionally, quantitative EF measurements will be made using integrated standard computer software for both the Power LV and the Hand LV. Each patient will serve as their own control.

Research Design: This is a prospective single center study designed to evaluate clinical techniques for diagnostic accuracy.

Clinical Relationships: It is anticipated that Hand LV will be and accurate method to estimate EF when compared to Power LV. (e.g. within a 5% difference is clinically is considered within inter and intra-individual variability.) This knowledge will allow clinicians to confidently perform Hand LV at the time of radial coronary angiography to estimate EF, reducing procedure time, contrast load and overall cost of the procedure.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adult patients greater than 18 years of age referred for radial coronary angiography with left ventriculography for clinical indications at the Loma Linda Heart and Surgical Hospital or the Loma Linda University Medical Center will be included in this study.

排除标准

  • Patients with a prosthetic aortic valve
  • Patients with severe aortic stenosis
  • Patients with suspected left main coronary artery disease
  • Patients with other contraindications to left ventriculography.
  • Patients with chronic kidney disease with a baseline creatinine ≥2.0 mg/dl if not already on renal replacement therapy will also be excluded