跳至主要内容
临床试验/NCT05612503
NCT05612503已完成不适用

Virtual Reality-based Exercises' Effects on Pulmonary Functions, Cardiopulmonary Capacity, Functional Performance, and Quality of Life in Children With Repaired Congenital Diaphragmatic Hernia

Qassim University2 个研究点 分布在 1 个国家目标入组 52 人开始时间: 2021年1月10日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
52
试验地点
2
主要终点
Pulmonary function test, forced vital capacity

研究概览

简要总结

The study has been designed to investigate the effect of 12 weeks of using virtual reality based exercises on pulmonary functions, exercise capacity, functional performance, and quality of life in children with surgically-repaired congenital diaphragmatic hernia.

详细描述

Children with CDH have significant disruptions in their quality of life (QoL) due to their poor health, in this randomized controlled clinical trial, one important aspect of virtual reality is the interactivity of children and their interests in choosing the exercised game. Each child in two groups perform a specific virtual reality based respiratory exercises for 3 months.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Outcomes Assessor)

入排标准

年龄范围
6 Years 至 10 Years(Child)
性别
All
接受健康志愿者

入选标准

  • age between 6 and 10 years.
  • BMI was between 20 and 24 kg/m
  • surgically-repaired congenital diaphragmatic hernia.
  • respiratory distress symptoms.
  • under follow-up care in pediatric and physical therapy clinic.

排除标准

  • Children were excluded if they have growth abnormality.
  • neuromotor disorders.
  • children with cardiac problems.
  • unable to do understand all procedures.

结局指标

主要结局

Pulmonary function test, forced vital capacity

时间窗: after 12 weeks

A pulmonary function test was conducted for all participants using a spirometry analyzer (Autospiro-507; Minato Medical Science; Osaka. Japan).

Pulmonary function test, forced expiratory volume in the first second

时间窗: after 12 weeks

A pulmonary function test was conducted for all participants using a spirometry analyzer (Autospiro-507; Minato Medical Science; Osaka. Japan).

Pulmonary function test, FEV1/FVC ratio

时间窗: after 12 weeks

performed using a spirometer (Autospiro-507; Minato Medical Science; Osaka. Japan)., (forced expiratory volume in the first second/ forced vital capacity) FEV1/FVC ratio was recorded.

Exercise capacity assessment

时间窗: after 12 weeks

Cardiopulmonary pulmonary exercise test using the Bruce treadmill test was used to asess the exercise capacity.

次要结局

  • Functional performance assessment(after 12 weeks)
  • Pediatric Quality of Life Inventory(after 12 weeks)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Maged Basha

Assistant Professor, College of Medical Rehabilitation, Qassim University

Qassim University

研究点 (2)

Loading locations...

相似试验