跳至主要内容
临床试验/NCT03246282
NCT03246282暂停早期 1 期

A Polychromatic Light Emitting Diode System to Deliver Low Dose Light Directly Into a Peripheral Intravascular Catheter: A Pain Reduction Study

John W. Reeves, MD1 个研究点 分布在 1 个国家目标入组 150 人开始时间: 2017年2月8日最近更新:
适应症
干预措施
相关药物

试验速览

阶段
早期 1 期
状态
暂停
发起方
入组人数
150
试验地点
1
主要终点
The use of polychromatic light therapy delivered through an intravascular catheter to assess the change in self-reported VAS pain score.

研究概览

简要总结

This study uses a prospective non-randomized, non-controlled design. One Hundred Fifty (150) subjects presenting with pain will be enrolled into a single treatment group The purpose of the study is to evaluate the feasibility of PLEDS for PIV catheter light delivery for pain reduction, through change between baseline average pain and final average VAS score. The absence of a control group is based on the following reason: The purpose of this investigation is to further the understanding of the feasibility of PLEDS for PIV catheter light delivery for pain management. Further, the results of this investigation will be used (internally only) to determine if subject-perceived reductions in pain warrant proceeding with more controlled, targeted and possibly randomized studies.

详细描述

This study uses a prospective non-randomized, non-controlled design. One Hundred Fifty (150) subjects presenting with pain will be enrolled into a single treatment group The purpose of the study is to evaluate the feasibility of Polychromatic Light Emitting Diode System (PLEDS) for Peripheral Intravenous (PIV) catheter light delivery for pain reduction, through change between baseline average pain and final average VAS score. The absence of a control group is based on the following reason: The purpose of this investigation is to further the understanding of the feasibility of PLEDS for PIV catheter light delivery for pain management. Further, the results of this investigation will be used (internally only) to determine if subject-perceived reductions in pain warrant proceeding with more controlled, targeted and possibly randomized studies.

PIV therapy has been used for decades as an effective therapy to maintain proper hydration and electrolyte levels. Additionally, PIV therapy can be infused with various agents, including supplements and pharmacological agents. Low-energy light therapy has been established as an alternative treatment for a myriad of medical conditions including reduction of pain. The concurrent administration of low-light therapy and PIV therapy may serve as a viable therapy for the treatment of pain associated with various medical conditions. Accordingly, this study is designed to assess the feasibility of low light therapy via PLEDS integrated into a standard PIV catheter for the purposes of reduction of pain.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Supportive Care
盲法
None

入排标准

年龄范围
18 Years 至 70 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Voluntarily signed informed consent form (see Informed Consent Forms)
  • Ages 18-70
  • Non-Pregnant Female Participants
  • Self-reported perceived pain score via "Brief Pain Inventory - Short Form" score of 2 or more.
  • No breastfeeding for 1 week prior to enrollment
  • Birth control measures to be used throughout the duration of the study for women of child bearing potential
  • Powerful antioxidants (e.g. oral antioxidants, Vitamin C and E, glutathione or Myer's cocktail IV infusion therapy) will not be used on treatment days

排除标准

  • Active infection along potential intravenous catheter sites
  • Use of anti-inflammatory medications on day of treatment and no more than 400mg per day for over 30 days
  • Suffering from blood clotting disorders (hypercoagulable condition, thrombocytosis, etc.)
  • Participated in a clinical study in the last 14 days
  • Breastfeeding
  • Currently taking photosensitizing agents

研究组 & 干预措施

Treatment Group

Experimental

Polychromatic light emitting diode system is a non-significant risk device that administers low-dose light generated by light emitting diode(s). A small adapter attaches directly to a standard 20-guage catheter that threads a small fiber optic through the distal end of the catheter. The optic terminates at the proximal end of the catheter. Polychromatic light is emitted to illuminate the catheter near the site of catheter entrance. Concurrently, normal saline flows through the optic adapter, into and through the 20-gauge catheter.

Device: UVL1000 Treatment Station Drug: Normal Saline 0.9% Infusion Solution Bag Device: Peripheral Catheterization

干预措施: UVL1000 Treatment Station (Device)

Treatment Group

Experimental

Polychromatic light emitting diode system is a non-significant risk device that administers low-dose light generated by light emitting diode(s). A small adapter attaches directly to a standard 20-guage catheter that threads a small fiber optic through the distal end of the catheter. The optic terminates at the proximal end of the catheter. Polychromatic light is emitted to illuminate the catheter near the site of catheter entrance. Concurrently, normal saline flows through the optic adapter, into and through the 20-gauge catheter.

Device: UVL1000 Treatment Station Drug: Normal Saline 0.9% Infusion Solution Bag Device: Peripheral Catheterization

干预措施: Normal Saline 0.9% Infusion Solution Bag (Drug)

Treatment Group

Experimental

Polychromatic light emitting diode system is a non-significant risk device that administers low-dose light generated by light emitting diode(s). A small adapter attaches directly to a standard 20-guage catheter that threads a small fiber optic through the distal end of the catheter. The optic terminates at the proximal end of the catheter. Polychromatic light is emitted to illuminate the catheter near the site of catheter entrance. Concurrently, normal saline flows through the optic adapter, into and through the 20-gauge catheter.

Device: UVL1000 Treatment Station Drug: Normal Saline 0.9% Infusion Solution Bag Device: Peripheral Catheterization

干预措施: Peripheral Catheterization (Device)

结局指标

主要结局

The use of polychromatic light therapy delivered through an intravascular catheter to assess the change in self-reported VAS pain score.

时间窗: 2 weeks

To evaluate the feasibility of PLEDS for PIV catheter light delivery for the purposes of pain reduction, through assessing the change between baseline average pain (via "Brief Pain Inventory - Short Form") and final average VAS score (via the "Per Treatment VAS Score Form") following treatment administration.

次要结局

未报告次要终点

研究者

发起方
John W. Reeves, MD
申办方类型
Other
责任方
Sponsor Investigator
主要研究者

John W. Reeves, MD

John W. Reeves, MD

White Clover Research Foundation

研究点 (1)

Loading locations...

相似试验

已完成
不适用
Safety and Feasibility of Polychromatic Light Emitting Diode for Peripheral Catheter Illumination During Peripheral Intravenous Delivery of Normal SalineQuality of LifeFatigue
NCT02785133UVLrx Therapeutics3,063
进行中(未招募)
1 期
Estudio prospectivo, aleatorizado, controlado con placebo, doble-ciego, multicéntrico, en grupos paralelos, para evaluar la eficacia, seguridad y tolerabilidad de bosentan en pacientes con hipertensión pulmonar tromboembólica crónica (HPTC) inoperable - BENEFIT
EUCTR2005-001965-33-ESActelion Pharmaceuticals Ltd.3
进行中(未招募)
不适用
Antithrombotic triple therapy and its effects on coagulation markers in venous and shed blood
EUCTR2012-001814-41-ATMedizinische Universität Wien; Universitätsklinik für Klinische Pharmakologie60
进行中(未招募)
不适用
An randomized, controlled, investigator-blinded, prospective, mono-centre study to evaluate the efficacy of fosfomycin versus meropenem in patients with complicated urinary tract infections - urosepsis/fosfo vs. meropenemThis study will primarily address the question of the efficacy of intravenous fosfomycin 4 g b.i.d. in the therapy of patients presenting with complicated urinary tract infection. These data will be compared to meropenem administered intravenously at a dose of 2 g b.i.d.MedDRA version: 9.1Level: LLTClassification code 10046571Term: Urinary tract infection
EUCTR2007-005112-37-ATMedizinische Universität Wien, Abteilung für Interne Medizin I240
招募中
Unknown
MantraTM Surgical Robotic System, Model 3.0 - Interventional Clinical Study for 10 patients.
CTRI/2024/06/068556Sudhir Srivastava Innovations Pvt. Ltd