跳至主要内容
临床试验/NCT00312390
NCT00312390撤回不适用

Amblyopia and Neurovascular Coupling in the Retina of Humans

Medical University of Vienna2 个研究点 分布在 1 个国家开始时间: 2003年7月最近更新:
适应症

试验速览

阶段
不适用
状态
撤回
试验地点
2
主要终点
Retinal vessel diameter

研究概览

简要总结

The visual disorder of amblyopia affects 2% to 3% of the population. Amblyopia is a developmental condition that is characterized by reduced vision of the eye due to the presence of a sensory impediment during visual development, such as strabismus (ocular misalignment) or anisometropia (unequal refractive error), occurring early in life. Recent studies in humans and animals point towards a cortical locus for the processing deficit in amblyopia, revealing sensory deficits at the signal cell level that include reduced spatial resolution, reduced contrast sensitivity, and a reduced number of binocular neural cells. In the retina, however, no abnormalities have yet been reported.

Like in the brain blood flow in the retina is coupled to neuronal activity. This phenomenon has been measured by different study groups with non invasive techniques in the brain and retina. We therefore use a Zeiss fundus camera for the assessment of retinal vessel diameters. This so called retinal vessel analyzer (RVA) is a combination of a fundus camera connected to a high resolution video camera equipped with a software based analyzing system. An unprecedented reproducibility and sensitivity of retinal vessel diameter measurements is attained with this system. In addition this system allows real time analysis of retinal vessels as well as off-line determinations from video tape. A special provocation test, which minimizes risk and discomfort to the subject under study is applied through the illumination pathway of the fundus camera: Diffuse luminance flicker is used as a stimulus to augment intrinsic mechanisms by which the retina can vary the vascular supply, in correspondence with local variations of functional activity. This system allows to study the flicker response of retinal vessels, which is within a magnitude of 6 to 8%.

However, the exact mechanisms underlying this phenomenon are not fully understood. Especially in the eye it is not clear whether it is an exclusive metabolic effect within the retina and the surrounding blood vessels or dependent of central regulatory brain functions.

The purpose of the current study is to improve our understanding of the mechanisms underlying flicker evoked responses of retinal blood vessels in humans. It is not clear whether the retina of amblyopic eyes can regulate retinal blood flow in response to increased metabolic demands as induced during flicking light stimulation. A detail understanding of the metabolic and functional processes within the retina of patients with amblyopia is a prerequisite for further research to prevent amblyopia.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Parallel
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 60 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • Inclusion criteria for healthy subjects:
  • Women and men, aged between 18 and 60 years
  • Matched with regard to age, sex and smoking status
  • Normal findings in the medical history and physical examination unless the investigator considers an abnormality to be clinically irrelevant
  • Normal ophthalmic findings, ametropia of less than 3.0 dpt
  • Inclusion criteria for patients with amblyopia as a result of anisometropia or strabismus:
  • Normal ophthalmic findings except amblyopia on one eye resulting from anisometropia or strabismus with a visual acuity between log Mar 0.3 and 0.7 (Snellen 0.2-0.5) with best correction on the amblyopic eye and 0.1 (Snellen 0.9) or better on the contralateral eye
  • Anisometropia of more 3 dpt (patients with anisometropia)
  • Women and men, aged between 18 and 60 years
  • Normal findings in the medical history and physical examination unless the investigator considers an abnormality to be clinically irrelevant

排除标准

  • Regular use of medication, abuse of alcoholic beverages, participation in a clinical trial in the 3 weeks preceding the study
  • pregnancy
  • Treatment in the previous 3 weeks with any drug
  • Symptoms of a clinically relevant illness in the 3 weeks before the first study day
  • Blood donation during the previous 3 weeks

结局指标

主要结局

Retinal vessel diameter

时间窗: 10 minutes

Time course of diameter changes induced by flicker light stimulation

时间窗: 10 minutes

次要结局

未报告次要终点

研究者

申办方类型
Other

研究点 (2)

Loading locations...

相似试验