Comparison of Clinical Outcomes After Cataract Surgery With and Without Capsular Tension Ring
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 52
- 主要终点
- Best corrected visual acuity
研究概览
简要总结
This study was set up to identify clinical outcomes including a refractive shift or change in IOL calculation accuracy and optical quality after Ophtec® capsular tension ring in the eyes without zonular instability.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Control
- 时间视角
- Retrospective
入排标准
- 年龄范围
- 40 Years 至 79 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •age between 40 and 79 years
- •no history of eye surgery or glaucoma
- •a transparent central cornea
- •pupil dilation at the preoperative examination of at least 6.0 mm
- •absence of biomicroscopic signs of pseudoexfoliation
- •normal fundus examination
排除标准
- •presence of ocular disease that might affect the visual outcome (e.g., color vision disturbance, chronic uveitis)
- •presence of ocular disease that might affect contrast sensitivity function (e.g., glaucoma, maculopathy, high myopia)
结局指标
主要结局
Best corrected visual acuity
时间窗: 1 month after capsular tension ring and intraocular lens implantation (cataract surgery) using capsular tension ring
Visual acuity measurement using refractive error correction
refractive error
时间窗: 1 month after capsular tension ring and intraocular lens implantation (cataract surgery) using capsular tension ring
Autokeratometry (KR-7100; Topcon, Tokyo, Japan) and manifested refraction were performed to examine refractive errors
Anterior chamber depth
时间窗: 3 months after capsular tension ring and intraocular lens implantation (cataract surgery) using capsular tension ring
obtained with a Scheimpflug imaging system (Pentacam; OCULUS Optikgeräte GmbH, Wetzlar, Germany)
Ocular aberrations
时间窗: 1month after capsular tension ring and intraocular lens implantation (cataract surgery) using capsular tension ring
measured using the ray-tracing aberrometer (iTrace, Tracey Technologies, Houston, TX, USA) at a pupil size of 5 mm in mesopic conditions, without pharmacologic dilatation
次要结局
- constrast sensitivity(3 months after capsular tension ring and intraocular lens implantation (cataract surgery) using capsular tension ring)
- Best corrected visual acuity(3 months after capsular tension ring and intraocular lens implantation (cataract surgery) using capsular tension ring)
- posterior capsular opacity grades(3 months after capsular tension ring and intraocular lens implantation (cataract surgery) using capsular tension ring)
- refractive error(3 months after capsular tension ring and intraocular lens implantation (cataract surgery) using capsular tension ring)
- Ocular aberrations(3 months after capsular tension ring and intraocular lens implantation (cataract surgery) using capsular tension ring)
