NCT02002364Unknown不适用
A Comparison Between Flexible Single Use Endoscopes (Ambu aScopes) and Reusable Flexible Endoscopes Used as a Standard of Car When Intubation the Trachea Via an Aura-I Supraglottic Airway Device
适应症
试验速览
- 阶段
- 不适用
- 入组人数
- 100
- 试验地点
- 4
- 主要终点
- Duration of intubation. From the endoscope enters the supraglottic-airway-device to CO2-curve is seen
研究概览
简要总结
In patient who are predicted to be difficult to intubate with a standard direct laryngoscope well use flexible optical intubation via a supraglottic airway devise (the Ambu Aura-i). Patients are randomly assigner to a single- or a multiple- use flexible optical scope.
We hypothesize that intubation is obtained equally effective with both types of flexible scopes
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •ASA physical status 1-3 and evaluated pre-operatively and found suitable for tracheal intubation with a flexible optical scope via the SAD and scheduled for elective surgery/anesthesia and are conscious about their rights and consequences of participating in the study.
- •The patient must have one or two of the following predictors of difficult tracheal intubation:
- •Modified Mallampati score > 2 (= "no parts of the Uvula is visible")
- •a thyromental distance of less then or equal to 6.5 cms
- •Combined movement in head and neck < 90 degrees
- •Mouth-opening less the 4 cm (but must be larger then 2.5 cm)
- •Inability to protrude the teeth n the lower jaw beyond the upper incisors
- •BMI > 40 combined with a neck-circumference > 43 cms
- •Upper-lip-bite-test > 2
- •Previous difficult intubation or laryngoscopy (If more then two criteria are fulfilled the patient should be considered intubated awake instead. . But the upper-lip-bite-test and the prognation-beyond the incisors test represents a similar thing, namely the inability to sub-luxate the lower jaw, the if both these findings are positive it is only considered as counting for one.
排除标准
- •ASA physical status 4 or 5
- •contraindications for use of the SAD
- •Patients in whom intubation via a SAD has previously failed
- •Patients at risk of aspiration from the gastrointestinal channel
- •diseases in mouth, pharynx or larynx that precludes the use of a SAD
- •Patients in whom the cricothyroid membrane cannot be localized preanaesthetically
- •Patients in whom the doctor making the pre-anaesthetic evaluation finds in need of an awake intubation
- •Patients with possible Creutzfeldt-Jacobs disease or contraindication against the use of non-autoclavable equipment r risk of cross contamination with prions
结局指标
主要结局
Duration of intubation. From the endoscope enters the supraglottic-airway-device to CO2-curve is seen
时间窗: Measured during tracheal intubation at induction of anesthesia
次要结局
- Number of attempts at placing the supraglottic-airway-device (SAD)(From anesthesia induction and the following 10 minutes during securing of the airway)
- number of attempts at placing the flexible endoscope in the trachea(From anesthesia induction and the following 10 minutes)
- number of attempts at intubation(From anesthesia induction and during the following 10 minutes during airway management)
- Total time for placement of SAD and endoscopy and intubation(During induction of anesthesia and the following 10 minutes during airway management)
- The best glottic view obtained(After anesthesia induction and during the following 10 minutes during airway management)
- The ease of passage of the flexible endoscope via the SAD(During induction and airway management)
- The anesthesiologists' satisfaction with the procedure(During induction of anesthesia and within the 30 minutes hereafter)
- The quality of the endoscopically obtained image(During induction of anesthesia and the following 10 minutes during airway management)
- Postoperative sore throat, dysphonia or dysphagia one hour after extubation(AT the time 1 hour after extubation of the trachea)
研究者
Michael Seltz Kristensen
Consultant anaesthetist
Rigshospitalet, Denmark
研究点 (4)
Loading locations...
相似试验
已完成
不适用
Flexible Intubation Scope With or Without Video Laryngoscope in Supporting Endotracheal Tube Placement in Patients With Head and Neck Cancer Before SurgeryHead and Neck NeoplasmNCT03757091M.D. Anderson Cancer Center143
已完成
不适用
Comparison of Two Novel Indirect Laryngoscopes to the Macintosh Laryngoscope in Patients With Cervical Spine Immobilization.ImmobilizationNCT01032460University College Hospital Galway90
Unknown
不适用
Comparison of Two Laryngoscopes: Single-use Device Laryngobloc ® (SU) Versus Reusable Handle With Disposable Metal Blade (R)Contamination of the HandlesQuality of the LaryngoscopyNCT01632085University Hospital, Strasbourg, France480
已完成
不适用
Comparison of Different Video Laryngoscopes in a Manikin With Immobilized Cervical SpineTracheal IntubationNCT01210092University of Cologne25
已完成
不适用
Comparison of the Glidescope and Macintosh Laryngoscope for Double Lumen Endotracheal Tube IntubationLung DiseaseNCT01404780University Health Network, Toronto70