Comparison of Optic Nerve Sheath Diameters Measured by Optic Ultrasonography Before and After Lumbar Puncture in Idiopathic Intracranial Hypertension Patients
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 47
- 试验地点
- 2
- 主要终点
- Correlation between intracranial pressure change and optic nerve sheath diameter
研究概览
简要总结
Idiopathic intracranial hypertensionis a type of increased intracranial pressure. Diagnosis is made by lumbar puncture, which is an invasive technique. The relationship between ICP and optic nerve sheath diameters (ONSD) were examined in our study. Thus, it was investigated whether the optic nerve sheath diameter could be used in the diagnosis of IIH. In the present study, it was found that ONSD measurement by optic USG significantly reflects increased ICP and decreasing pressure via LP is rapidly reflects to ONSD measurement. And it is suggested that ONSD measurements by optic USG, a non-invasive method, can be used in the diagnosis and follow-up of IIH patients.
详细描述
Backgrounds: Idiopathic intracranial hypertension (IIH); symptoms include headaches, blurred vision and papilledema which may lead to permanent visual loss. Definitive diagnosis of IIH usually requires the measurement of intracranial pressure (ICP) via lumbar puncture (LP) which is an invasive technique. In our study, the relationship between ICP and optic nerve sheath diameters (ONSD) were examined. Thus it was investigated whether optic nerve ultrasonography (USG) is a useful tool instead of LP for the diagnosis of IIH.
Methods: A total of 25 patients who applied to the neurology clinics of Ankara Numune Training and Research Hospital between May 2014 and December 2015 and were diagnosed with IIH were included in the study. The control group consisted of 22 individuals who applied with other complaints than headaches. ONSD was measured from both eyes before and after the LP. After pre-LP measurements were taken, opening and closing CSF (cerebrospinal fluid) pressure was measured. In the control group, ONSD was measured with optic USG.
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Parallel
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 17 Years 至 65 Years(Child, Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Clinical diagnosis of idiopathic intracranial hypertension
- •Adults aged 17-65
排除标准
- •In cranial imaging, if pathology such as tumor, sinus vein thrombosis is detected
- •People for whom lumbar puncture is contraindicated or cannot be performed
结局指标
主要结局
Correlation between intracranial pressure change and optic nerve sheath diameter
时间窗: Baseline to 10-15 minutes after lumbar puncture
Before and after lumbar puncture, optic nerve sheath diameter measured with optic ultrasonography. The correlation of these measurements with cerebrospinal fluid opening and closing pressures was investigated.
次要结局
未报告次要终点
研究者
Zehra Bozdoğan Şenel
Medical Doctor, Principal Investigator
Ege University