跳至主要内容
临床试验/NCT06087250
NCT06087250已完成不适用

Reliability of Carotid Artery Corrected Flow Time Predicting Fluid Responsiveness in Geriatric Patients.

Marmara University1 个研究点 分布在 1 个国家目标入组 40 人开始时间: 2023年8月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
40
试验地点
1
主要终点
carotid corrected flow time (cFT)

研究概览

简要总结

Carotid blood flow and corrected carotid flow time (Carotid Flow Time (FTc)) provide information about left ventricular preload and inversely correlate with systemic vascular resistance. The reliability in assessing fluid responsiveness has been demonstrated in studies involving invasive cardiac output measurements. In the elderly patient population where arterial elasticity can be compromised, there is no existing data in literature that determines the reliability and predictive value of FTc after general anesthesia induction.

详细描述

Doppler ultrasound of the common carotid artery has begun to be used as a potential non-invasive tool for assessing hemodynamic status. Its non-invasive nature, ability to be applied independently of the patient's position, ease of application due to the superficial location of the carotid artery, and resistance to intrathoracic pressure changes are among its advantages. Carotid blood flow and corrected carotid flow time (Carotid Flow Time (FTc)) provide information about left ventricular preload and inversely correlate with systemic vascular resistance. Additionally, the velocity time integral (VTI) measuring blood flow through the carotid artery during systole, when multiplied by the cross-sectional area of the carotid artery, allows for the determination of flow within the carotid artery. The reliability in assessing fluid responsiveness has been demonstrated in studies involving invasive cardiac output measurements. In the elderly patient population where arterial elasticity can be compromised, there is no existing data in literature that determines the reliability and predictive value of FTc after general anesthesia induction.

研究设计

研究类型
Observational
观察模型
Case Crossover
时间视角
Prospective

入排标准

年龄范围
65 Years 至 100 Years(Older Adult)
性别
All
接受健康志愿者

入选标准

  • geriatric patient (older than 65 years of age) having surgery under general anesthesia

排除标准

  • Common carotid artery stenosis, common carotid artery disease

结局指标

主要结局

carotid corrected flow time (cFT)

时间窗: 1 hour

the ability ofc FT to predict fluid responsiveness

次要结局

  • cutt-of value of cFT(1 hour)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Beliz Bilgili

Associated Prof, M.D

Marmara University

研究点 (1)

Loading locations...

相似试验

Carotid Artery Corrected Flow Time and Fluid... | 临床试验